Rapid antibiotic susceptibility tests (ASTs) are essential for quick selection of effective drugs to treat bacterial infections at an early stage. However, the most widely used phenotypic ASTs in clinical practice often require 24 - 48 hours of pre-culture enrichment and 4 - 20 hours of testing. They are too slow to guide therapy, even with the most rapid protocol. Here, we report a lab-on-a-silicon chip (LOSC) system, which integrates arrays of silicon nanowire field-effect transistor (SiNWFET) sensors with high-throughput cell-collection microfluidics for rapid ASTs. The microfluidics concentrate bacteria into picoliter-scale chambers within minutes, eliminating the need for pre-cultivation. Embedded SiNWFETs sensitively track antibiotic-induced metabolic pH shifts, enabling AST by detecting rapid metabolic inhibition in susceptible bacteria. Using an unbuffered culturing medium, LOSC achieves sample-to-result times within 20 minutes for clinically isolated E. coli strains. With its electrical readout and compact design, LOSC offers a low-cost, rapid, and portable AST solution for point-of-care diagnostics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zheqiang Xu, Victoria C Nolan, Yingtao Yu, Petra Muir, Sanna Koskiniemi, Zhen Zhang. 2026-07-31. A lab-on-a-silicon-chip platform for all-electrical antibiotic susceptibility tests with a sample-to-results time within 20 minutes. https://doi.org/10.1126/sciadv.aeb2880

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det