Search arXivSearch

arXiv · 2508.13417

Full Spectrum Modeling of In Situ Gamma-ray Detector Measurements with a Focus on Precipitation-Induced Transients

Abstract

Gamma-ray detectors that are deployed outdoors experience increased event rates during precipitation due to the attendant increase in Rn-222 progeny at ground level. The increased radiation due to these decay products (Pb-214 and Bi-214) has been studied for many decades in applications such as atmospheric science and radiation protection. For those applications radon progeny signatures are the signal of interest, while in the fields of radiological and nuclear security and aerial radiological mapping they are a nuisance. When searching for radiological contamination or missing sources, an analyst must take precipitation into account to reduce false alarms, in addition to accounting for static background signatures. To train advanced search algorithms, an effort has been underway to generate synthetic gamma-ray event data that represent a realistic urban area, including occasional rain events to add to the realism. This manuscript describes an effort to analyze and model gamma-ray spectra measured during rainfall by a NaI(Tl) detector located outdoors in order to derive accurate source terms for Pb-214 and Bi-214 at a high frequency (less than 1 minute). All known sources of background were quantitatively modeled across the full gamma-ray spectrum, so that the Pb-214 and Bi-214 activity concentrations on the ground could be inferred from a linear model fit to each spectrum. A physically motivated model was applied to the data to further smooth the fits, which had the benefit of yielding information about the concentrations of the progeny in rainwater and their apparent age, making this the first time full-spectrum modeling has been used for continuous measurements of radon progeny. This approach could lead to studies of radon progeny on shorter timescales than previously possible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mark S. Bandstra, James M. Ghawaly, Douglas E. Peplow, Daniel E. Archer, Brian J. Quiter, Tenzing H. Y. Joshi, Andrew D. Nicholson, Michael J. Willis, Irakli Garishvili, Andrew J. Rowe, Brandon R. Longmire, Jason T. Nattress. 2025-10-07. Full Spectrum Modeling of In Situ Gamma-ray Detector Measurements with a Focus on Precipitation-Induced Transients. https://arxiv.org/abs/2508.13417

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det