Search arXivSearch

arXiv · 2508.14157

The high-speed X-ray camera on AXIS: design and performance updates

Abstract

AXIS, a Probe mission concept now in a Phase A study, will provide transformative studies of high-energy astrophysical phenomena thanks to its high-resolution X-ray spectral imaging. These capabilities are enabled by improvements to the mirror design that greatly increase the X-ray throughput per unit mass; and to the detector system, which operates more than an order of magnitude faster than heritage instruments while maintaining excellent spectral performance. We present updates to the design of the AXIS High-Speed Camera, a collaborative effort by MIT, Stanford University, the Pennsylvania State University, and the Southwest Research Institute. The camera employs large-format MIT Lincoln Laboratory CCDs that feature multiple high-speed, low-noise output amplifiers and an advanced single-layer polysilicon gate structure for fast, low-power clock transfers. A first lot of prototype CCID100 CCDs has completed fabrication and will soon begin X-ray performance testing. The CCDs are paired with high-speed, low-noise ASIC readout chips designed by Stanford to provide better performance than conventional discrete solutions at a fraction of the power consumption and footprint. Complementary Front-End Electronics employ state-of-the-art digital video waveform capture and advanced signal processing to further deliver low noise at high speed. The Back-End Electronics provide high-speed identification of candidate X-ray events and transient monitoring that relays fast alerts of changing sources to the community. We highlight updates to our parallel X-ray performance test facilities at MIT and Stanford, and review the current performance of the CCD and ASIC technology from testing of prototype devices. These measurements achieve excellent spectral response at the required readout rate, demonstrating that we will meet mission requirements and enable AXIS to achieve world-class science.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Eric D. Miller, Catherine E. Grant, Robert Goeke, Marshall W. Bautz, Christopher Leitz, Kevan Donlon, Steven W. Allen, Sven Herrmann, Abraham D. Falcone, F. Elio Angile, Tanmoy Chattopadhyay, Michael Cooper, Mallory A. Jensen, Jill Juneau, Beverly LaMarr, Andrew Malonis, R. Glenn Morris, Peter Orel, Abigail Y. Pan, Steven Persyn, Artem Poliszczuk, Gregory Y. Prigozhin, Ilya Prigozhin, Andrew Ptak, Christopher Reynolds, Haley R. Stueber, Keith Warner, Daniel R. Wilkins. 2025-08-19. The high-speed X-ray camera on AXIS: design and performance updates. https://arxiv.org/abs/2508.14157

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM