Search arXivSearch

arXiv · 2508.19962

A cryogenic chamber setup for superfluid helium experiments with optical fiber and electrical access

Abstract

Superfluid helium is a prototypical quantum liquid. As such, it has been a prominent platform for the study of quantum many body physics. More recently, the outstanding mechanical and optical properties of superfluid helium, such as low mechanical dissipation and low optical absorption, have positioned superfluid helium as a promising material platform in applications ranging from dark matter and gravitational wave detection to quantum computation. However, experiments with superfluid helium incur a high barrier to entry as they require incorporation of complex optical and electrical setups within a hermetically sealed cryogenic chamber to confine the superfluid. Here, we report on the design and construction of a helium chamber setup for operation inside a dilution refrigerator at Millikelvin temperatures, featuring electrical and optical fiber access. By incorporating an automated gas handling system, we can precisely control the amount of helium gas inserted into the chamber, rendering our setup particularly promising for experiments with superfluid helium thin films, such as superfluid thin film optomechanics. Using silicon nanophotonic resonators, we demonstrate precise control and in-situ tuning of the thickness of a superfluid helium film on the sub-nanometer level. By making use of the exceptional tunability of the superfluid film thickness, we demonstrate optomechanically induced phonon lasing of phononic crystal cavity third sound modes in the superfluid film and show that the lasing threshold crucially depends on the film thickness. The large internal volume of our chamber (V_chamber = 1l) is adaptable for integration of various optical and electrical measurement and control techniques. Therefore, our setup provides a versatile platform for a variety of experiments in fundamental and applied superfluid helium research.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alexander R. Korsch, Niccolò Fiaschi, Simon Gröblacher. 2025-08-27. A cryogenic chamber setup for superfluid helium experiments with optical fiber and electrical access. https://doi.org/10.1063/5.0249931

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det