Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

Abstract

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M. F. Albakry, I. Alkhatib, D. Alonso-Gonzalez, J. Anczarski, T. Aralis, T. Aramaki, I. Ataee Langroudy, C. Bathurst, R. Bhattacharyya, A. J. Biff, P. L. Brink, M. Buchanan, R. Bunker, B. Cabrera, R. Calkins, R. A. Cameron, C. Cartaro, D. G. Cerdeno, Y. -Y. Chang, M. Chaudhuri, J. H. Chen, R. Chen, N. Chott, J. Cooley, H. Coombes, P. Cushman, R. Cyna, S. Das, S. Dharani, M. L. di Vacri, M. D. Diamond, M. Elwan, S. Fallows, E. Fascione, E. Figueroa-Feliciano, S. L. Franzen, A. Gevorgian, M. Ghaith, G. Godden, J. Golatkara, S. R. Golwala, R. Gualtieri, J. Hall, S. A. S. Harms, C. Hays, B. A. Hines, Z. Hong, L. Hsu, M. E. Huber, V. Iyer, V. K. S. Kashyap, S. T. D. Keller, M. H. Kelsey, K. T. Kennard, Z. Kromer, A. Kubik, N. A. Kurinsky, M. Lee, J. Leyva, B. Lichtenberga, J. Liu, Y. Liu, E. Lopez Asamard, P. Lukens, R. Lopez Noe, D. B. MacFarlane, R. Mahapatra, J. S. Mammo, A. J. Mayer, P. C. McNamara, E. Michaud, E. Michielin, K. Mickelson, N. Mirabolfathi, M. Mirzakhani, B. Mohanty, D. Mondal, D. Monteiro, J. Nelson, H. Neog, J. L. Orrell, M. D. Osborne, S. M. Oser, L. Pandey, S. Pandey, R. Partridge, P. K. Patel, D. S. Pedrerosa, W. Peng, W. L. Perry, R. Podviianiuk, M. Potts, S. S. Poudel, A. Pradeep, M. Pyle, W. Rau, T. Reynold, M. Rios, A. Roberts, A. E. Robinson. 2025-08-27. Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning. https://arxiv.org/abs/2508.20090

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det