Search arXivSearch

arXiv · 2508.20862

Dipole Localization Using An Integrated Radio Frequency Atomic Magnetometer

Abstract

Optically-pumped atomic magnetometers have previously been used in arrays to reject interference from far away sources and enable the sensitive detection of local sources of radio frequency (RF) signals, useful, for instance, in the detection of low field NMR signals in an unshielded environment. We now demonstrate a complementary scheme in which four magnetometer measurements are used to locate in three dimensions a nearby radio frequency source. The methodology relies on the measurement of a radio frequency vector at two different positions and modeling the source as a magnetic dipole of known orientation. In contrast to coil detection, magnetometers have the advantage of measuring signals in a 2D plane, and do not inductively couple to their environment or each other, making them a strong candidate for localization of hidden RF sources. For this demonstration, we use only a single RF magnetometer to make four measurements of a synchronous and oriented dipole source, but it is to be expected that this could be replaced by four magnetometers working simultaneously. In addition, this work is greatly aided by the introduction of a fully integrated magnetometer, in which all optics, including lasers, are safely enclosed into a compact head with flexible wired connections. The portable, as well as safe, nature of the sensor make it quite valuable for in the field work.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ayse Marasli, Thomas Kornack, Casey Oware, Karen L. Sauer. 2026-02-08. Dipole Localization Using An Integrated Radio Frequency Atomic Magnetometer. https://arxiv.org/abs/2508.20862

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det