Search arXivSearch

arXiv · 2509.14516

Event-LAB: Towards Standardized Evaluation of Neuromorphic Localization Methods

Abstract

Event-based localization research and datasets are a rapidly growing area of interest, with a tenfold increase in the cumulative total number of published papers on this topic over the past 10 years. Whilst the rapid expansion in the field is exciting, it brings with it an associated challenge: a growth in the variety of required code and package dependencies as well as data formats, making comparisons difficult and cumbersome for researchers to implement reliably. To address this challenge, we present Event-LAB: a new and unified framework for running several event-based localization methodologies across multiple datasets. Event-LAB is implemented using the Pixi package and dependency manager, that enables a single command-line installation and invocation for combinations of localization methods and datasets. To demonstrate the capabilities of the framework, we implement two common event-based localization pipelines: Visual Place Recognition (VPR) and Simultaneous Localization and Mapping (SLAM). We demonstrate the ability of the framework to systematically visualize and analyze the results of multiple methods and datasets, revealing key insights such as the association of parameters that control event collection counts and window sizes for frame generation to large variations in performance. The results and analysis demonstrate the importance of fairly comparing methodologies with consistent event image generation parameters. Our Event-LAB framework provides this ability for the research community, by contributing a streamlined workflow for easily setting up multiple conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Adam D. Hines, Alejandro Fontan, Michael Milford, Tobias Fischer. 2026-03-04. Event-LAB: Towards Standardized Evaluation of Neuromorphic Localization Methods. https://arxiv.org/abs/2509.14516

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

J-PARSE: Jacobian-based Projection Algorithm for Resolving Singularities Effectively in Inverse Kinematic Control of Serial Manipulators

J-PARSE is an algorithm for smooth first-order inverse kinematic control of a serial manipulator near kinematic singularities. The commanded end-effector velocity is interpreted component-wise, according to the available mobility in each dimension of the task space. First, a substitute ''Safety'' Jacobian matrix is created, keeping the aspect ratio of the manipulability ellipsoid above a threshold value. The desired velocity is then projected onto non-singular and singular directions, and the latter projection scaled down by a factor informed by the altered mobility. A right-inverse of the non-singular Safety Jacobian is applied to the modified command. In the absence of joint limits and collisions, this ensures safe transition into and out of low-mobility configurations, guaranteeing locally stable reaching behavior towards target poses within, on the boundary of, and outside the workspace. The behavior is further guaranteed to be locally asymptotically stable if the starting and target configurations are not exactly singular, even if they are nearly singular. Velocity control with J-PARSE is benchmarked against approaches from the literature, illustrating its use of a single tuning parameter to simultaneously achieve high reaching accuracy and stable behavior. Applications in teleoperation, servoing, and learning are demonstrated. Videos and code are available at https://jparse-manip.github.io/.

cs.RO

NeMo-map: Neural Implicit Flow Fields for Spatio-Temporal Motion Mapping

Safe and efficient robot operation in complex human environments can benefit from good models of site-specific motion patterns. Maps of Dynamics (MoDs) provide such models by encoding statistical motion patterns in a map, but existing representations use discrete spatial sampling and typically require costly offline construction. We propose a continuous spatio-temporal MoD representation based on implicit neural functions that directly map coordinates to the parameters of a Semi-Wrapped Gaussian Mixture Model. This removes the need for discretization and imputation for unevenly sampled regions, enabling smooth generalization across both space and time. Evaluated on two public datasets with real-world people tracking data, our method achieves better accuracy of motion representation and smoother velocity distributions in sparse regions while still being computationally efficient, compared to available baselines. The proposed approach demonstrates a powerful and efficient way of modeling complex human motion patterns and high performance in the trajectory prediction downstream task. The code is publicly available at https://github.com/test-bai-cpu/nemo-map.

cs.RO

Spatiotemporal Calibration of Doppler Velocity Logs for Underwater Robots

The calibration of extrinsic parameters and clock offsets between sensors for high-accuracy performance in underwater SLAM systems remains insufficiently explored. Existing methods for Doppler Velocity Log (DVL) calibration are either constrained to specific sensor configurations or rely on oversimplified assumptions, and none jointly estimate translational extrinsics and time offsets. We propose a Unified Iterative Calibration (UIC) framework for general DVL sensor setups, formulated as a Maximum A Posteriori (MAP) estimation with a Gaussian Process (GP) motion prior for high-fidelity motion interpolation. UIC alternates between efficient GP-based motion state updates and gradient-based calibration variable updates, supported by a provably statistically consistent sequential initialization scheme. The proposed UIC can be applied to IMU, cameras and other modalities as co-sensors. We release an open-source DVL-camera calibration toolbox. Beyond underwater applications, several aspects of UIC-such as the integration of GP priors for MAP-based calibration and the design of provably reliable initialization procedures-are broadly applicable to other multi-sensor calibration problems. Finally, simulations and real-world tests validate our approach.

cs.RO