This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, USA. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m3 each. The detector uses liquid argon both as target and as active media. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground laboratory, in a 3 year duration run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams, at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment, have been completely re-designed and rebuild, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the Icarus Collaboration. Design, installation, testing, commissioning and operation is the result of a common effort of CERN, Fermilab and INFN Groups.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F. Abd Alrahman, P. Abratenko, N. Abrego-Martinez, A. Aduszkiewicz, F. Akbar, L. Aliaga Soplin, M. Artero Pons, J. Asaadi, W. F. Badgett, B. Behera, V. Bellini, R. Benocci, J. Berger, S. Berkman, O. Beltramello, S. Bertolucci, M. Betancourt, A. Blanchet, F. Boffelli, M. Bonesini, T. Boone, B. Bottino, A. Braggiotti, J. Bremer, S. J. Brice, V. Brio, C. Brizzolari, H. S. Budd, A. Campani, A. Campos, D. Carber, M. Carneiro, I. Caro Terrazas, H. Carranza, F. Castillo Fernandez, A. Castro, S. Centro, G. Cerati, M. Chalifour, P. Chambouvet, A. Chatterjee, D. Cherdack, S. Cherubini, N. Chithirasreemadam, T. E. Coan, A. Cocco, M. R. Convery, L. Cooper-Troendle, S. Copello, H. Da Motta, M. Dallolio, A. A. Dange, A. de Roeck, S. Di Domizio, L. Di Noto, D. Di Ferdinando, M. Diwan, S. Dolan, L. Domine, S. Donati, R. Doubnik, F. Drielsma, J. Dyer, S. Dytman, C. Fabre, A. Falcone, C. Farnese, A. Fava, N. Gallice, F. G. Garcia, C. Gatto, M. Geynisman, D. Gibin, A. Gioiosa, W. Gu, A. Guglielmi, G. Gurung, K. Hassinin, H. Hausner, A. Heggestuen, B. Howard, R. Howell, Z. Hulcher, I. Ingratta, C. James, W. Jang, Y. -J. Jwa, L. Kashur, W. Ketchum, J. S. Kim, D. -H. Koh, J. Larkin, Y. Li, C. Mariani, C. M. Marshall, S. Martynenko, N. Mauri, K. S. McFarland, D. P. Méndez, A. Menegolli. 2026-04-09. Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab. https://arxiv.org/abs/2509.18392

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Search for dark matter in a signature with a four-prong large-radius jet in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A search for a pair of nonprompt dark matter (DM) candidates produced in association with an initial-state radiation jet, in a signature containing a four-prong large-radius jet, is presented. The signal model contains a heavy vector or axial-vector mediator, which produces long-lived dark-sector particles that decay to a stable DM particle and a light boson, which decays to quarks. The analysis is based on data collected in the years 2016$-$2018 with the CMS detector at the LHC in proton-proton collisions at $\sqrt{s}$ = 13 TeV, corresponding to an integrated luminosity of 138 fb$^{-1}$. Signal candidates feature large-radius jets, which are identified using a jet substructure tagger based on a graph neural network. The large-radius jet aims to reconstruct the decay of light DM mediators into four quarks, which are produced in association with two stable DM particles. The standard model background contributions are estimated from data using dedicated control regions. The missing transverse momentum spectrum is probed for a potential signal over the expected background. No significant excess over the standard model expectation is observed. Upper limits at 95% confidence level are set on the signal strength as functions of either the mediator mass or the relevant coupling. This is the first search for a pair of nonprompt DM candidates in the Lorentz-boosted topology, characterized by a large-radius jet and large missing transverse momentum.

hep-ex

Charge-dependent atmospheric muon flux at 17 GV geomagnetic cutoff with the mini-ICAL detector

The Iron CALorimeter (ICAL) detector at the India-Based Neutrino Observatory (INO) was conceived as an underground experiment designed to measure atmospheric neutrino oscillation parameters. As part of the R\&D programme, a scaled prototype (mini-ICAL), 85\,ton, approximately 1/600$^{\mathrm{th}}$ the mass of the full detector, was constructed at the IICHEP Transit Campus, Madurai (altitude 150\,m; latitude 9.9372$^\circ$\,N; longitude 78.013$^\circ$\,E; geomagnetic latitude 1.44$^\circ$\,N; vertical cutoff rigidity 17\,GV) and operated between 2018 and 2022. The prototype enabled measurements of charge-dependent cosmic muon spectra in the vicinity of the geomagnetic equator and provided an important validation of detector performance, reconstruction algorithms, and simulation frameworks for the ICAL experiment. Differential fluxes of $μ^{-}$ and $μ^{+}$ were measured over the momentum range $\sim$\,1--5\,GeV/c. The obtained momentum spectra are systematically lower than those reported at sites with smaller geomagnetic cutoff rigidities, consistent with the suppression of low- and intermediate-rigidity primary cosmic rays at the 17\,GV cutoff. The measurements are compared with predictions from different hadronic interaction models available in CORSIKA simulations.

hep-ex

Laboratory constraints on peV-scale mass splitting between ordinary and sterile neutron states

Sterile states of matter, represented by a parallel ``mirror'' sector, may contribute to the observed dark matter in the Universe. We investigated the parameter space of neutron $(n)$ to mirror-neutron $(n')$ oscillations, in the case where the two states are not necessarily mass-degenerate, taking into account interactions in the mirror sector. By tuning the magnitude of an applied magnetic-field in the range $5~μ\mathrm{T} < B < 360~μ\mathrm{T}$ to corresponding resonance conditions for finite mass splitting, we derive exclusion limits for the $n-n'$ oscillation time constant reaching about $20~\text{s}$ over the mass-difference range $0.3 - 22~\text{peV}$. In parts of this parameter range, our limits exceed the model-dependent neutron-star-cooling bound, providing the first experimental constraints in this scenario that are more stringent than this astrophysical estimate.

hep-ex