Search arXivSearch

arXiv · 2509.21883

Enhancing Particle Identification in Helium-Based Drift Chambers Using Cluster Counting Insights from Beam Test Studies

Abstract

Particle identification in gaseous detectors traditionally relies on energy loss measurements (dE/dx); however, uncertainties in total energy deposition limit its resolution. The cluster counting technique (dN/dx) offers an alternative approach by exploiting the Poisson-distributed nature of primary ionization, providing a statistically robust method for mass determination. Simulation studies with Garfield++ and Geant4 indicate that dN/dx can achieve twice the resolution of dE/dx in helium-based drift chambers. However, experimental implementation is challenging due to signal overlap in the time domain, complicating the identification of electron peaks and ionization clusters. This paper presents novel algorithms and modern computational techniques to address these challenges, facilitating accurate cluster recognition in experimental data. The effectiveness of these algorithms is validated through four beam tests conducted at CERN, utilizing various helium gas mixtures, gas gains, and wire orientations relative to ionizing tracks. The experiments employ a muon beam (1 GeV/c to 180 GeV/c) with drift tubes of different sizes and sense wire diameters. The analysis explores the Poisson nature of cluster formation, evaluates the performance of different clustering algorithms, and examines the dependence of counting efficiency on the beam particle impact parameter. Furthermore, a comparative study of the resolution achieved using dN/dx and dE/dx is presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W. Elmetenawee, M. Abbrescia, M. Anwar, G. Chiarello, A. Corvaglia, F. Cuna, B. D'Anzi, N. De Filippis, F. De Santis, M. Dong, E. Gorini, F Grancagnolo, F. G. Gravili, K. Johnson, S. Liu, M. Louka, A. Miccoli, M. Panareo, M. Primavera, F. M. Procacci, A. Taliercio, G. Tassielli, A. Ventura L. Wu, G. Zhao. 2025-10-30. Enhancing Particle Identification in Helium-Based Drift Chambers Using Cluster Counting Insights from Beam Test Studies. https://arxiv.org/abs/2509.21883

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det