Search arXivSearch

arXiv · 2510.03539

Rasnik 3-point alignment system: algorithm, control framework, and its applications

Abstract

Rasnik is a three-point optical displacement sensor originally developed for particle detector alignment in high-energy physics experiments, including the muon chambers of L3 at LEP and ATLAS at the LHC. The system has evolved from four-quadrant photodiodes to CMOS pixel sensors with custom ChessField coded masks, enabling absolute position measurement with no cumulative drift due to absolute value coded. Key advantages include electromagnetic immunity through purely optical measurement principles, working distances from 50 mm to 15 m, and multi-degree-of-freedom sensitivity perpendicular to the optical axis. RasCal, a comprehensive control and analysis software, is presented in this paper and its real-time image processing shows 5 pm/$\sqrt{\text{Hz}}$ spatial resolution. With GPU acceleration, 274.5 Hz is achieved during live camera acquisition and 109 Hz on CPU. In maximum-throughput configurations, the processing rates exceed 300 Hz on simple consumer hardware. System performance is demonstrated across diverse applications: 5 pm/$\sqrt{\text{Hz}}$ displacement sensitivity is achieved in the VATIGrav setup, dynamic behavior is characterized with a Watt's linkage. In addition, the lack of cumulative drift due to absolute coding with minimal thermal sensitivity under controlled conditions is used for vibration and thermal characterization of photodiode mounts for the LISA space mission. Millisecond-level command latency and thread-safe multi-camera support are provided by the RasCal software, establishing it as a robust and cost-effective precision measurement solution for demanding alignment applications in gravitational-wave detectors and space instrumentation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anoop Nagesh Koushik, Harry van der Graaf, Kevin Ravensberg, Rene M. Wanders, Sena N. Gomashie, Nick van Remortel, Joris van Heijningen. 2025-10-03. Rasnik 3-point alignment system: algorithm, control framework, and its applications. https://arxiv.org/abs/2510.03539

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TCAD + Allpi$\text{x}^2$ Simulation study of MALTA2, a Depleted Monolithic Active Pixel Sensor for future tracking

In this work, a hybrid simulation framework combining TCAD and Allpi$\text{x}^2$ is presented to investigate the sensor properties of MALTA2, a depleted monolithic active pixel sensor designed for future tracking. The study starts from 3D modeling and transient simulations in TCAD, with generic doping profiles and simple well structures. The resulting doping profiles and electric field are extracted and fed into Allpi$\text{x}^2$ for high-statistics Monte Carlo simulations in both DUT-only and full-telescope mode. Simulations reveal a strong dependence of sensor performance, specifically the detection efficiency and cluster size, on the doping concentration of the N-type blanket at the sensor surface. The doping concentration is then optimized by comparing simulations with measurement data. The active depth of the depleted region of the MALTA2 sensor is estimated in both simulations and measurements using a grazing angle method, in which the sensor is positioned at various inclinations relative to the beam, covering angles from 0 to 60 degrees. Excellent agreement on active depth is obtained with the optimal doping concentration, showing a deviation of 2\% from the measured value at a threshold of 450\,$\text{e}^-$. Consequently, the framework offers a generic toolkit for sensor studies without requiring proprietary information.

physics.ins-det

A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams

We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 $μ$m-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 $μ$s transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.

physics.ins-det

Charge-Carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping

Diamond detectors are attractive for operation in harsh radiation environments because they combine radiation tolerance, fast signal formation, and low leakage current. Realistic detector-response simulations require an accurate description of charge-carrier mobility and trapping, which determine both signal amplitude and timing. In this work, we extend \allpix{}, a modular end-to-end detector simulation framework, with diamond-specific transport models. The implementation includes field-dependent mobility parameterizations for electrons and holes and an effective trapping model based on the charge collection distance (CCD), providing a detector-level interface to material quality and radiation-damage measurements. The mobility description is validated in the negligible-trapping limit using single-crystalline CVD diamond by comparing simulated drift velocities and transient-current signals with published reference data. For polycrystalline CVD diamond, the CCD-based trapping model is evaluated using experimentally measured CCD values and compared with laboratory transient-current-technique waveforms. The simulations reproduce the measured drift-velocity behavior in scCVD and the reduced charge collection and degraded transient response observed in pcCVD. The presented implementation enables detector-level studies of charge collection, pulse formation, and timing performance in diamond sensors using experimentally accessible transport and trapping parameters, and provides a practical framework for simulation-driven detector development and radiation-damage studies.

physics.ins-det