Search arXivSearch

arXiv · 2510.03586

Human brain high-resolution diffusion MRI with optimized slice-by-slice B0 field shimming in head-only high-performance gradient MRI systems

Abstract

The purpose of this study is to propose a brain tissue-selective, optimized slice-by-slice B0 field shimming for high-resolution brain diffusion MRI. We incorporated actual gradient fields of X, Y, and Z gradient coils in the calculation of the shimming coefficients in dynamic slice-by-slice B0 field shimming to minimize B0 field inhomogeneity (i.e., Delta B0) in deep-learning segmented brain tissues. Diffusion MRI with oscillating gradient spin echo (OGSE) at 55 Hz and pulsed gradient spin echo (PGSE) (approximated at 0 Hz) were obtained in phantoms and healthy volunteers using a head-only high-performance gradient 3T MRI system. In each diffusion MRI acquisition, standard static volumetric shimming and the proposed shimming method were applied separately, and mean/axial/radial diffusivities (MD/AD/RD) and fractional anisotropy (FA) were estimated. In phantom, the root-mean-square of Delta B0 in areas with high gradient nonlinearity was reduced by 7 Hz when incorporating actual gradient field in dynamic shimming. Compared to static shimming, dynamic shimming reduced root-mean-square of voxel displacement of each slice by a maximum of 5-10 voxels in single-shot EPI acquisition at 1-2 mm in-plane resolution in phantom, and a maximum of 3 voxels in human brains. Improved accuracy of MD/AD/RD/FA in the superior region of the brain, brainstem, and cerebellum were observed by applying dynamic shimming and/or two-shot EPI acquisition. MD(55 Hz)-MD(0 Hz) showed higher values in T2 FSE hypo-intensity region by applying dynamic shimming. We concluded that diffusion MRI with brain tissue-selective, dynamic slice-by-slice B0 effectively improves the accuracy of diffusivity characterization in high-resolution images.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Patricia Lan, Sherry S. Huang, Chitresh Bhushan, Xinzeng Wang, Seung-Kyun Lee, Raymond Y. Huang, Jerome J. Maller, Jennifer A. McNab, Ante Zhu. 2025-10-04. Human brain high-resolution diffusion MRI with optimized slice-by-slice B0 field shimming in head-only high-performance gradient MRI systems. https://arxiv.org/abs/2510.03586

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Voxel-Matching NORDIC: Non-local patch formation by time-series similarity increases tSNR in high-resolution BOLD fMRI

Submillimeter functional magnetic resonance imaging (fMRI) based on blood-oxygenation-level-dependent (BOLD) signal enables the study of brain function at the submillimeter level, uncovering insights into fine-scale organisations like cortical layers and columns. However, its inherently low contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) often limit its reliability and applicability. Noise Reduction with Distribution Corrected Principal Components Analysis (NORDIC PCA) is a locally low-rank denoising algorithm that reduces thermal noise levels in BOLD fMRI in a local patch manner. However, local patches often contain a mixture of signals from multiple tissues that negatively affects the low-rank structure of the patches, which limits the denoising capabilities of the algorithm. We propose an alternative approach for patch formation by gathering similar non-local voxels, dubbed voxel-matching (VM) NORDIC. The results on submillimeter-resolution BOLD fMRI data indicate that VM-NORDIC effectively promotes the low rank of the patches by boosting signal redundancy, allowing for more efficient noise attenuation. Moreover, the method barely affects spatial smoothness due to the non-local voxel selection based on time-series similarity. In particular, VM-NORDIC outperforms standard NORDIC with default local patching (Standard-NORDIC) in terms of temporal SNR (tSNR) (~9-90% larger than Standard-NORDIC; ~23-250% larger than the original) and spatial smoothness estimates (~20% of the smoothness induced by Standard-NORDIC). These improvements are fundamental to improving the validity and precision of fMRI studies at submillimeter resolutions.

physics.med-ph

Computed Tomography Reconstruction Algorithm Using Markov Random Field Model

X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small computational cost. Under low-dose or sparse-view conditions, however, FBP often amplifies noise, severely degrading the reconstructed images. In this study, we evaluated the performance of a Bayesian CT reconstruction algorithm based on the Markov random field model under such adverse conditions. Through simulations, we demonstrated that the proposed algorithm shows higher reconstruction performance than FBP under both low-dose and sparse-view conditions. The hyperparameters are estimated by minimizing the Bayesian free energy, enabling adaptive reconstruction that reflects the noise characteristics of the observed projection data. These results suggest that the proposed algorithm can broaden the applicability of CT to dose-sensitive applications and time-constrained measurements, where only limited observed projection data are available.

physics.med-ph

Charge Collection Efficiency in Air-Vented Plane-Parallel Ionisation Chambers at Ultra-High Dose Rates: A Self-Consistent Garfield++ Monte Carlo Model Including Space-Charge Effects and Ion Recombination

Ultra-high dose rate (UHDR) irradiation used in FLASH radiotherapy can lead to significant reductions in charge collection efficiency (CCE) in plane-parallel ionisation chambers (PPICs) due to enhanced ion recombination, while the high charge densities involved can also induce strong space-charge-induced electric-field distortions. To investigate these coupled effects, we extended the Garfield++ Monte Carlo particle-transport framework by implementing ion--ion recombination and self-consistent space-charge electric field calculations. The developed Monte Carlo model couples particle transport, electron attachment, recombination processes, and dynamic electric-field distortions. The implementation was validated against analytical and numerical models from the literature. Excellent agreement was obtained for the free electron fraction (FEF), CCE, induced current, and electric field evolution under UHDR conditions. The simulations show that space charge can locally increase the electric field by more than a factor of four or reduce it to nearly zero in some regions of the chamber. The results further suggest that the reduction of the CCE under UHDR conditions is mainly driven by the decrease of the FEF caused by electric-field-dependent electron attachment. This finding indicates that the complex problem of recombination under UHDR conditions may be largely governed by the evolution of the FEF, opening promising perspectives for the development of improved analytical models and real-time correction methods for ionisation chamber dosimetry under UHDR irradiation conditions. This work provides a flexible and self-consistent Monte Carlo framework for investigating recombination phenomena and improving dosimetry models for FLASH radiotherapy.

physics.med-ph