Search arXivSearch

arXiv · 2510.24766

Data sorting modes of phoswich detector array

Abstract

The different data-sorting modes of the phoswich detector array PARIS used for detecting high-energy (4$-$10 MeV) $γ$ rays are investigated. The characteristics including time resolution, energy resolution and detection efficiency under various modes are studied. The present study shows that PARIS has capabilities of rejecting escape and pileup events when used for decay spectroscopy. Notably, the methods presented in this work refer specifically to the $β$-decay experiment of $^{80g+m}$Ga conducted with three PARIS clusters comprising 27 phoswich detectors, rather than to a general report on the PARIS array or its overall performance for in-beam spectroscopy. Compared with the 2"$\times$2"$\times$2" LaBr$_3$(Ce) detector (Ciemała et al., 2009), even in individual mode, PARIS provides significant suppression of single- and double-escape peaks and reduces background via vetoing function of the outer-volume NaI(Tl) crystals. In contrast to the common approach of adding back the energies in LaBr$_3$(Ce) and NaI(Tl) to increase the detection efficiency of the full-energy peak, using NaI(Tl) as a veto shield provides a superior trade-off for applications where spectral purity is essential. Employing add-back analysis within each cluster of nine phoswiches or between all phoswiches could enhance full-energy peak efficiency and further suppress escape peaks and background. Applying a multiplicity condition provides a further suppression but simultaneously lowers the statistics of full-energy peaks.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R. Li, D. Verney, C. Delafosse, M. N. Harakeh, A. Maj, F. Didierjean, L. Al Ayoubi, H. Al Falou, P. Bednarczyk, G. Benzoni, F. Le Blanc, V. Bozkurt, M. Ciemała, F. C. L. Crespi, I. Deloncle, C. Gaulard, A. Gottardo, V. Guadilla, J. Guillot, K. Hadyńska-Klek, F. Ibrahim, N. Jovancevic, A. Kankainen, M. Kmiecik, M. Lebois, T. Martínez, P. Napiorkowski, B. Roussiere, Yu. G. Sobolev, M. Stanoiu, I. Stefan, S. Stukalov, D. Thisse, G. Tocabens. 2026-02-04. Data sorting modes of phoswich detector array. https://doi.org/10.1016/j.nima.2026.171337

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det