Search arXivSearch

arXiv · 2511.05453

Development and characterization of MPGD-based transition radiation detectors

Abstract

Transition Radiation Detectors (TRDs) are useful for electron identification and hadron suppression in high energy nuclear and particle physics experiments. Conventional wire-chamber TRDs face operational limitations due to space charge effects, motivating the replacement of the amplification stage with MicroPattern Gaseous Detectors (MPGDs). This work explores different MPGD technologies - Gas Electron Multiplier (GEM), Micro-Mesh Gaseous Structure (Micromegas), and Resistive Micro-Well ($μ$RWELL) - as alternative TRD amplification stages. We report on the design, construction, and in-beam characterization of multiple MPGD-based TRD prototypes exposed to 3-20 GeV mixed electron-hadron beams at the Fermilab Test Beam Facility and at the CERN SPS H8 beamline. Each detector consisted of a multi-layered radiator, an approximately 2 cm deep drift region, an MPGD amplification stage optimized for X-ray transition radiation detection in a Xe:CO$_{2}$ (90:10) gas mixture, and a two-dimensional readout. The GEM-based TRD prototype achieved a pion suppression factor of about 8 at 90% electron efficiency, while the Micromegas-based prototype - with an added GEM preamplification layer - demonstrated improved operational stability and clear TR photon discrimination. The $μ$RWELL prototype achieved stable operation but limited signal gain. Geant4-based studies confirmed the observed trends and highlighted the sensitivity of the TR yield to cathode material and radiator configuration. These studies represent the first in-beam measurements of Micromegas- and $μ$RWELL-based TRDs, along with discussion of the performance capabilities of a triple-GEM-TRD. The results demonstrate the feasibility of MPGDs as scalable, high-rate amplification structures for next-generation TRD applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lauren Kasper, Alexander Austregesilo, Fernando Barbosa, Cody Dickover, Sergey Furletov, Yulia Furletova, Kondo Gnanvo, Senta Vicki Greene, Lubomir Pentchev, Sourav Tarafdar, Julia Velkovska. 2026-02-27. Development and characterization of MPGD-based transition radiation detectors. https://doi.org/10.1016/j.nima.2026.171403

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det