arXiv · 2511.05643
Transmission Efficiency of the Recoil Mass Spectrometer EMMA at TRIUMF
Abstract
The mean transmission efficiency of the EMMA recoil mass spectrometer at TRIUMF has been measured with 6 different angular apertures at 17 kinetic energy/charge deviations with respect to the central, reference trajectory. Measurements performed using a 148Gd alpha source installed at the target position of the spectrometer are compared to ion-optical calculations and Monte Carlo simulations. The transmission efficiency as a function of angle and kinetic energy/charge is described empirically using piecewise Gaussian functions whose parameters are fit to the data.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
B. Davids, N. E. Esker, J. Jaeyoung, Y. K. Kim, K. Pak, M. Williams. 2025-11-07. Transmission Efficiency of the Recoil Mass Spectrometer EMMA at TRIUMF. https://doi.org/10.1016/j.nima.2026.171295
Cite the original work for its findings. Save a collection to share your selection of sources.