Search arXivSearch

arXiv · 2511.13634

Exploring the production of Terbium-161 in the Brazilian Multipurpose Reactor

Abstract

The Brazilian Multipurpose Reactor (RMB) was conceived to meet national needs for radioisotope production, materials irradiation testing, and neutron beam applications. In addition to its 30~MW pool-type reactor, the RMB complex will include additional facilities for radioisotope production and related applications. $^{161}Tb$ is a promising radionuclide for radiopharmaceutical therapy, offering decay properties similar to $^{177}Lu$ but with additional conversion and Auger electrons that enhance dose delivery to cancer cells. In light of this emerging radioisotope, this study explores the potential production of $^{161}Tb$ in the RMB through neutron irradiation of enriched $Gd_{2}O_{3}$ targets. Monte Carlo (MCNP) simulations provided detailed neutron flux distributions, which were used as input for ORIGEN calculations of isotope buildup. Assuming 10 mg targets enriched to 97.5% in $^{160}Gd$, a 40-day irradiation, and a thermal flux of $2 \cdot 10^{14}$ $n/cm^{2}s$, the results indicate that $^{161}Tb$ activity reaches approximately 4.5 GBq after 14 days ($\approx 450 GBq/g$), in agreement with data from other research reactors. Building on prior studies that demonstrated the RMB's capability to irradiate larger targets, terabecquerel-scale yields appear feasible. These findings highlight the RMB's potential to support domestic production of emerging therapeutic radionuclides such as $^{161}Tb$. The potential for isotopic enrichment of $^{160}Gd$ using the AVLIS method is also discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fernando Cozim Melges, Jhonatha Ricardo Santos, Luiz Paulo de Oliveira, Alexandre Pinho dos Santos Souza, Carlos Gabriel Santos da Silva, Iberê Souza Ribeiro Júnior, Barbara Perez Gonçalves Silva, Marco Antonio Stanojev Pereira, Frederico Antonio Genezini. 2025-11-17. Exploring the production of Terbium-161 in the Brazilian Multipurpose Reactor. https://arxiv.org/abs/2511.13634

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det