Data Center Control Against Sub-Synchronous Resonance: A Data-Driven Approach

Abstract

Data centers host a variety of essential services such as cloud computing and artificial intelligence. Electric grid operators, however, have limited knowledge of the reliability risks of data center interconnection due to their unique operational characteristics. An emerging concern is the sub-synchronous resonance (SSR) which refer to unexpected voltage/current oscillations at typical frequencies below 60/50 Hz. It remains unknown whether and how the interactions between data centers and the grid may trigger resonances, equipment damages, and even cascading failures. In this paper, we focus on grid-connected data centers that draw electricity from the grid through power factor correction (PFC) converters. We conduct two-tone frequency sweep to investigate the data centers' impedance characteristics, i.e. magnitude and phase angle variations over frequencies, and showcase their deep dependence on compute workloads. The impedance modeling provides a direct approach to evaluating SSR risks and enable a cooperative mechanism to alarm and avoid resonance-prone situations. Building upon the impedance, a data-driven preventive controller is then established to raise early warnings of risky operation and suggest flexible workload management according to the given grid conditions. Through case study, we demonstrate how to use impedance to understand the unexpected interactions. Data-driven impedance is validated to show decent performance in capturing the unique impedance dips and tracking the impedance variations across a range of workload scenarios. The early warning and preventive control approaches are further effective to improve the safety margins with minimal workload rescheduling. The key findings of this work will provide valuable insights for grid operators and data center managers, and support preparation for future scenarios involving large-scale data center integration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Grant Ruan, Marija D. Ilic, Le Xie. 2025-11-18. Data Center Control Against Sub-Synchronous Resonance: A Data-Driven Approach. https://arxiv.org/abs/2511.14141

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Ensuring Stability of Non-Minimal Modes in Input-Output Data-Driven Representation

Many recent data-driven control approaches for linear time-invariant systems are based on output trajectory prediction using input-output data matrices. The system dynamics described by this predictor, which we refer to as the input-output data-driven representation, yields non-unique autoregressive with exogenous inputs (ARX) models having possibly unstable non-minimal modes. In this note, we show that the stability of these non-minimal modes is ensured by a certain choice of ARX model, which coincides with the minimum-norm least-squares predictor using the Moore-Penrose inverse of the data matrix. This stability guarantee holds regardless of the underlying system's stability. Moreover, the stability persists under sufficiently small noise in data when a suitably truncated Moore-Penrose inverse is used. Consequently, the ARX model need not be reduced to the true system order in order to avoid unstable additional modes.

eess.SY

Optimization-Based Formation Flight on Libration Point Orbits

A model predictive control (MPC) framework is developed for station-keeping in spacecraft formation flight along libration point orbits. At each control period, the MPC policy solves a multi-vehicle optimal control problem (MVOCP) that tracks a reference trajectory, while enforcing path constraints on the relative motion of the formation. The control policy makes use of a limited set of control nodes consistent with operational constraints that allow only a small number of maneuver opportunities per revolution. To promote recursive feasibility, path constraints are progressively tightened across the prediction horizon. An isoperimetric reformulation of the constraints is used to prevent inter-sample violations. The resulting MVOCP is a nonconvex program, which is solved via sequential convex programming. The proposed approach is evaluated in a high-fidelity ephemeris model under uncertainties for a formation along the near-rectilinear halo orbit (NRHO), and subject to path constraints on inter-spacecraft separation and relative Sun phase angle. The results demonstrate maintenance of a spacecraft formation that satisfies the path constraints with realistic cumulative propellant consumption.

eess.SY

Certificates Synthesis for A Class of Observational Properties in Stochastic Systems: A Unified Approach

In this paper, we investigate the probabilistic formal verification of stochastic dynamical systems over continuous state spaces. Motivated by problems in state estimation and information-flow security, we introduce the notion of observational properties, which characterize the inferences an external observer can draw from system outputs. These properties are formulated as probabilistic hyperproperties based on HyperLTL over finite traces, yielding a unified framework that subsumes several existing notions studied separately in the literature. We reduce the verification problem to reachability analysis over an augmented structure that integrates the system dynamics with an automaton representation of the specification. Building on this construction, we develop stochastic barrier certificates that provide probabilistic guarantees for property satisfaction while avoiding explicit state-space discretization. The effectiveness of the proposed framework is demonstrated through a case study.

eess.SY