Effective Hyper-clutter Artifacts Suppression for Ultrafast Ultrasound Doppler Imaging

Abstract

Objective: Hyper-clutter artifacts (HCA), arising from strong tissue reflections or physiological motion, present persistent challenges in ultrafast ultrasound Doppler imaging, often obscuring surrounding small vessel flow signals, especially in fascial regions such as the renal capsule. This study proposes U-profile-based decluttering (UPBD), a robust and computationally efficient method that exploits singular value decomposition (SVD)-derived spatial singular vectors to suppress HCA in ultrafast Doppler imaging. Methods: UPBD analyzes intensity profile of each pixel along the singular-order dimension of the SVD-derived left singular vectors U. A pixel-wise clutter-energy ratio is computed to derive a spatially adaptive declutter weighting map, which is applied to the SVD-filtered flow signals. Results: UPBD was evaluated on multiple in vivo datasets. Quantitative assessments based on contrast-to-noise ratio (CNR) and contrast-to-tissue ratio (CTR) demonstrated significant improvements over conventional SVD filtering. For example, UPBD enhanced CTR from 7.3 dB to 21.7 dB in contrast-free pig kidney, 17.8 dB to 42.1 dB in contrast-enhanced pig kidney, 8.2 dB to 32.8 dB in human kidney, and -4.9 dB to 3.7 dB in 3D human liver. Conclusion: The proposed UPBD method effectively suppresses HCA while preserving blood flow signals with minimal extra computational cost and no need for extensive parameter tuning. Significance: UPBD serves as a lightweight, easily integrated post-processing method that enhances HCA suppression, enabling broader application of SVD-based ultrafast Doppler imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lijie Huang, Jingyi Yin, Jingke Zhang, U-Wai Lok, Ryan M. DeRuiter, Kaipeng Ji, Yanzhe Zhao, Tao Wu, James D. Krier, Xiang-yang Zhu, Andrew J. Bentall, Andrew D. Rule, Thomas D. Atwell, Lilach O. Lerman, Shigao Chen, Chengwu Huang. 2025-11-26. Effective Hyper-clutter Artifacts Suppression for Ultrafast Ultrasound Doppler Imaging. https://arxiv.org/abs/2511.21833

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Explicit pixel-value correction of lateral response artifacts in radiochromic film dosimetry: Evaluation of single-, double-, and triple-channel methods

Background:Flatbed scanners introduce a lateral response artifact (LRA) perpendicular to lamp motion. Because LRA varies with position, pixel value (PV), color channel, and film model, it may violate the channel-common perturbation assumption of multichannel dosimetry. Purpose:To characterize PV-domain LRA in EBT4 and EBT-XD films, compare Lewis and Full corrections, and evaluate their effects on single-, double-, and triple-channel dosimetry. Methods:Seven films were scanned at seven lateral positions using a cyclic-shift design. For each position and RGB channel, center-equivalent response was modeled as PVc = A + B * PV. Lewis correction used two films with linear interpolation of A and B; Full correction used all center-local pairs with PCHIP interpolation of PVc - PV. Performance was assessed by portrait-landscape profile consistency and dose accuracy. Results: LRA was affine in PV, asymmetric about scanner center, and dependent on film model and channel. Both corrections reduced profile differences. Mean absolute profile differences across MU levels ranged from 1.4%-5.3% for EBT4 and 2.4%-6.8% for EBT-XD. The methods performed similarly for EBT4, while Full correction reduced discrepancies for several EBT-XD double- and triple-channel methods. Residual blue-channel errors limited blue, red-blue, and triple-channel performance. At 500 MU and above, red showed the best dose agreement; at 100 MU, both corrections increased deviations for several single-channel estimates. Full correction produced smaller deviations than Lewis in several EBT-XD conditions. Conclusions:LRA should be corrected in the raw-PV domain before dose reconstruction. Full correction better preserved profile consistency and dose accuracy, particularly for EBT-XD. Because improved profile consistency did not always improve central-dose agreement, both should be evaluated separately in commissioning.

physics.med-ph

Integration of Spectral CT with PET and SPECT: Bringing Tissue Composition Information to Molecular Imaging

Molecular imaging has been transformed by integrating positron emission tomography (PET) or single-photon emission computed tomography (SPECT) with x-ray computed tomography (CT). However, x-ray CT in hybrid imaging is used primarily for anatomical localization and for attenuation and scatter correction of emission data. Its ability to characterize tissue composition remains underutilized. Spectral CT, including dual-energy CT (DECT) and photon-counting CT (PCCT), can provide material-specific information, such as images of iodine concentration, bone or calcium fractions, electron-density, effective atomic number and other spatially-varying material properties. These capabilities create an opportunity to bring tissue-composition information into molecular imaging. In addition, spectral CT can also reduce CT artifacts and provide more accurate corrections for emission data. In this review, we discuss the technical basis, integration pathways, and translational opportunities for combining spectral CT with molecular imaging. We review sequential and integrated PET/DECT approaches, emerging PET/PCCT concepts, PET-enabled spectral CT, and extensions to SPECT/CT. We then examine how spectral CT information may improve attenuation correction, scatter correction, tissue-fraction correction, positron range correction, reconstruction priors, and dosimetry. Clinical and translational applications include contrast-enhanced molecular imaging, vascular and perfusion imaging, quantitative bone marrow imaging, musculoskeletal imaging, and theranostics. Overall, spectral CT integration may move hybrid molecular imaging toward tissue-composition-informed molecular imaging, in which radiotracer signals are interpreted within their material context.

physics.med-ph

Non-circular scan trajectories for reducing cone-beam artifacts in Gamma Knife CBCT images: a simulation study

Objective. Gamma Knife cone-beam computed tomography (CBCT) images are deteriorated by cone-beam artifacts whose magnitude increases along the superior direction. In this study, a novel scan trajectory compatible with the Gamma Knife CBCT system is optimized to reduce cone-beam artifacts, with the aim to replace the current 200-degree single-arc scan. Approach. Data sampling analysis with tomographic incompleteness maps indicates the level of undersampling across the field of view based on the geometry of the system and of a scan trajectory. Moreover, CBCT simulations are performed from a virtual phantom with disks aligned along the axial direction and from a CT reconstruction of a stereotactic end-to-end validation (STEEV) phantom. CBCT projections are simulated for a given scan trajectory through a polychromatic forward projection model with added noise and scatter, then the CBCT image is reconstructed using an iterative algorithm which minimizes weighted least squares. Main results. Both the incompleteness analysis and the CBCT simulations indicate adding lines to the current single-arc trajectory is more efficient to reduce cone-beam artifacts than adding more arcs, both in terms of number of additional projections and new artifacts. A line-arc-line trajectory with source axial steps of 3.5 mm removes virtually all cone-beam artifacts. The widths of the cone-beam artifacts created by the disks show a positive correlation between the artifact magnitude and the incompleteness value. Significance. A line-arc-line scan trajectory is promising to reduce cone-beam artifacts of the Gamma Knife CBCT images while being a compatible and reasonable trajectory for the current system design.

physics.med-ph