The paper reports on the timing resolution achieved with Low-Gain Avalanche Diodes (LGADs), optimised for extreme-fluence conditions, at the DESY Test Beam Facility using 4~GeV/c electrons. The LGADs adopt an $n$-in-$p$ technology with a $p^{+}$-type boron gain implant, co-implanted with carbon to mitigate acceptor deactivation due to irradiation. The substrate thickness of the sensors varies from 20 to 45~\micron, with an active area spanning from 0.75~$\times$~0.75 to 1.28~$\times$~1.28~mm$^{2}$. The experimental setup consisted of a 45~\micron-thick trigger sensor with an active area of 3.6~$\times$~3.6~mm$^{2}$, two device-under-test (DUT) planes, and a Photonis micro-channel plate photomultiplier tube (MCP) as a time reference. Data taking was performed at the ambient temperature of the facility, at 18$^{\circ}$C. The gain was measured between 7 and 40 across all non-irradiated sensors in the study. The timing resolution was calculated from a Gaussian fitting of the difference in times of arrival of a particle at the DUT and the MCP, using the constant fraction discriminator technique. A timing resolution of 26.4~\ps was achieved in 45~\micron-thick sensors, down to 16.6~\ps in 20~\micron-thick sensors, in the non-irradiation study. The combination of two 20~\micron-thick LGADs reached a timing resolution of 12.2~\ps. A set of 30~\micron-thick sensors irradiated with neutrons at fluences between 0.4~$\times$~10$^{15}$ and 2.5~$\times$~10$^{15}$~\mevneut were tested in the beam. These irradiated sensors achieved a gain between 7 and 30 using a similar apparatus but cooled with solidified CO$_{2}$ to -42$^{\circ}$C. A timing resolution of 20~\ps was obtained in these irradiated sensors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robert Stephen White, Marco Ferrero, Valentina Sola, Anna Rita Altamura, Roberta Arcidiacono, Maurizio Boscardin, Nicolo Cartglia, Matteo Centis Vignali, Tommaso Croci, Matteo Durando, Simone Galletto, Alessandro Fondacci, Leonardo Lanteri, Luca Menzio, Francesco Moscatelli, Giovanni Paternoster, Federico Siviero. 2026-04-02. Timing resolution from beam tests on thin LGADs down to 16.6 ps. https://doi.org/10.1016/j.nima.2026.171596

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det