Search arXivSearch

arXiv · 2512.05265

Real-time optimal quantum control for atomic magnetometers with decoherence

Abstract

Quantum entanglement, in the form of spin squeezing, is known to improve the sensitivity of atomic sensors to static or slowly varying fields. Sensing transient events presents a distinct challenge, requires different analysis tools, and has not been shown to benefit from entanglement in practically important scenarios such as spin-precession magnetometry. To address this, we apply concepts from continuous quantum measurements and estimation theory to optical atomic magnetometers, aiming to accurately model these devices, interpret their measurement data, control their dynamics, and achieve optimal sensitivity. Quantifying this optimal performance requires determining a fundamental quantum limit on sensitivity. We derive this limit, imposed by noise, and show that it scales at best linearly with sensing time and atom number N, ruling out any super-classical scaling. This limit is independent of the initial state, measurement, estimator, and measurement-based feedback, and depends only on the decoherence model and the strength of field fluctuations. Thus, finding an estimator that attains this bound proves the sensing strategy optimal. To approach this limit, we develop a quantum dynamical model scalable with N, based on a co-moving Gaussian approximation of the stochastic master equation, which includes measurement backaction and decoherence. This enables a real-time estimation and control architecture integrating an extended Kalman filter with a linear quadratic regulator. Simulating the magnetometer with our model and EKF+LQR strategy shows that quantum-limited tracking of constant and fluctuating fields is within reach of current atomic magnetometers. Our sensing strategy can also track biologically relevant signals, such as heartbeat-like waveforms, and drive the atomic ensemble into an entangled state, even when the measurement record is used for feedback but later discarded.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Julia Amoros-Binefa. 2025-12-04. Real-time optimal quantum control for atomic magnetometers with decoherence. https://arxiv.org/abs/2512.05265

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Iteratively decoded magic state distillation

We present numerical simulation results for the 7-to-1 and 15-to-1 state distillation circuits, constructed using transversal CNOTs acting on multiple surface code patches. The distillation circuits are decoded iteratively using the method outlined in [arXiv:2407.20976]. We show that, with a re-configurable qubit architecture, we can perform fast magic state distillation in $\sim\mathcal{O}(1)$ code cycles. We confirm that both circuits suppress an injected input logical error rate $p$ to $\mathcal{O}(p^3)$ in the presence of additional circuit-level noise. This is done with two types of stabiliser proxies, distilling logical $|-\rangle$ and $|Y\rangle$ states, the latter is the intended state of the 7-to-1 circuit while a stabiliser-proxy for the 15-to-1 circuit. We then also provide numerical evidences for actual $|T\rangle$ state distillation using the 15-to-1 circuit with a faulty-$T$ measurement, leveraging recent near-Clifford simulation tools. Finally, we outline how ZX-calculus and Pauli webs can be used to benchmark stabiliser proxies for these distillation circuits.

quant-ph

Enhanced measurements on quantum computers via the simultaneous probing of non-commuting Pauli operators

Measuring the state of quantum computers is a highly non-trivial task, with implications for virtually all quantum algorithms. A promising avenue is multi-copy schemes, where identical copies of a quantum state are measured jointly so that all Pauli operators within the considered observable can be simultaneously assessed. Here, we present a first implementation of such a two-copy scheme in a measurement protocol. Based on Bayesian statistics, it accurately estimates not only the average of the desired observable but also the error en route. This enables an adaptive shot-allocation algorithm that preferentially samples the most uncertain Pauli terms. In regimes with many non-commuting Pauli operators, this ``double'' scheme can outperform the state-of-the-art measurement protocol in minimizing total shots for a given precision. We also numerically confirm the finding in previous theoretical works that the two-copy scheme incurs an overhead due to the square-root relationship between the variance of measured quantities and the number of measurement shots.

quant-ph

Thermodynamics of a phaseonium-driven optomechanical Otto engine

We study an optomechanical Otto engine whose working medium is a single-mode cavity driven by beams of coherently prepared three-level phaseonium atoms. The atoms are not thermal reservoirs in the Gibbs sense; rather, their populations and ground-state coherence set the detailed-balance ratio of the cavity collision map, so that the field relaxes to a Gibbs state at an operational apparent temperature. We combine the finite-time collision-model dynamics with radiation-pressure work extraction and compare three reservoir preparations: a thermal reference at the same apparent temperatures, an incoherent atomic beam with the same populations, and the coherent phaseonium beam. We show that the phaseonium isochore charges the cavity passively: the cavity ergotropy and energy-basis coherence remain zero up to numerical precision, while the state converges to the Gibbs fixed point selected by the apparent detailed balance. We further estimate lower bounds on the cost of preparing the atomic populations and coherence, showing that the relevant advantage of phaseonium is a resource-preparation tradeoff rather than a cost-free enhancement over a thermal bath at the same temperature. Finally, we assess the finite-time performance of a two-cavity cascade with additive mechanical work accounting. Over the investigated coherence-phase range, the cascade produces approximately $47\%$--$52\%$ more power than the single-cavity engine while requiring only $65\%$--$68\%$ of the hot and cold phaseonium atoms needed by two independent engines, resulting in a $9\%$--$15\%$ enhancement of power per injected atom over a complete cycle.

quant-ph