Search arXivSearch

arXiv · 2512.05632

Modulation of Ionic Current Rectification in Short Unipolar Nanopores

Abstract

With controlled ionic current rectification (ICR) achieved through a strategically designed non-uniform surface charge distribution, short unipolar nanopores exhibit promising applications in nanofluidic sensors, ionic circuits, and ion amplifiers. By systematically investigating how the charged length on inner pore walls modulates ion transport, we found that both the maximum ICR degree and the corresponding charged-length proportion were influenced by nanopore parameters and simulation conditions. For 100 nm-long unipolar nanopores, the highest ICR degree is obtained at a charged-length proportion of ~0.3, due to the corresponding most significant ion enrichment and depletion inside the nanopore under opposite biases. This charged-length proportion of ~0.3 consistently appears as a characteristic value across most considered cases. For short unipolar nanopores, the presence of exterior surface charges significantly enhances the ICR degree by facilitating ion transport through nanopores. The effective widths of charged regions beyond nanopore borders on outer surfaces exhibit direct proportionality to the pore diameter, surface charge density, and applied voltage, and inverse proportionality to the pore length and salt concentration. Our research may provide useful guidance for the design of unipolar nanopores and porous membranes incorporating such charge configurations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hongwen Zhang, Long Ma, Di Liu, Tianyi Sui, Zuzanna S. Siwy, Yinghua Qiu. 2025-12-05. Modulation of Ionic Current Rectification in Short Unipolar Nanopores. https://doi.org/10.1016/j.jcis.2025.139274

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Charge Transfer with a Spin. I: A Variational Constrained-CASSCF Framework for Investigating Charge Transfer in the Presence of Spin-Orbit Coupling

Charge transfer in open-shell molecular systems can involve a delicate interplay between charge localization, orbital relaxation, and spin-orbit coupling (SOC), particularly near ground-excited state crossings. Here, we introduce a very inexpensive variational framework for treating these effects in odd-electron systems by extending the electron/hole-transfer Dynamically-weighted State-Averaged Constrained CASSCF (eDSC/hDSC) method to include SOC. Our method incorporates the SOC Hamiltonian directly into the variational orbital optimization through complex-valued spinor orbitals, allowing orbital and spin degrees of freedom to relax self-consistently while preserving the time-reversal symmetry of doublet states. The method achieves smooth potential energy surfaces and rapid self-consistent field (SCF) convergence; moreover, from physically small to artificially large SOC strengths, the calculation can be converged to very tight thresholds across the whole potential energy surface. While the results presented here are for systems with two charge centers, as shown in the appendix, the theory is quite general and can be adapted to either a system of $N$ charge centers or a metal-molecule surface with a continuum of states, so that charge transport (and not just charge transfer) can also be studied. The approach therefore provides a route towards ab initio studies of spin-dependent charge transfer and charge transport in molecular systems with nontrivial spin degrees of freedom.

physics.chem-ph

Charge Transfer with a Spin. II: A Framework for Diabatization which Localizes Charge and Spin

We investigate a diabatization procedure that localizes charges (in real space) and localizes spins (in spin space) for open-shell systems that exhibit charge transfer in the presence of spin-orbit coupling. The procedure is applied to a two-state crossing between pairs of Kramers-restricted doublet states (which can also be considered effectively a four-state crossing). To generate the relevant diabatic states, we employ a two-step optimization over complex-unitary rotations that sequentially maximizes dipole and spin moments through iterative Jacobi sweeps; the resulting update rules are effectively equivalent to those of approximate joint diagonalization (AJD) applied to charge and spin. The method converges rapidly and yields smooth diabatic potential energy surfaces that preserve dipole and spin properties (e.g., a smoothly varying spin quantization axis) along the reaction coordinate while maintaining time-reversal symmetry.

physics.chem-ph

Fixed-Dimensional Latent Flow for Generating Variable-Size 3D Molecules

Molecular size is coupled to composition, structure, and function, yet most 3D molecular generators require a predefined atom count. We introduce Equivariant-Free Transformer-Autoencoded Latent Flow Matching, a two-stage framework that samples a fixed-dimensional latent vector using flow matching and uses an autoregressive Transformer to determine molecular size, atom types, coordinates, and chemical attributes. Canonical atom ordering and rigid-pose alignment enable Transformers without equivariant layers, while decoded attributes guide bond reconstruction. On PCQM4Mv2, unconditional generation yields 87.9\% unique, novel molecules passing sanitization and PoseBusters checks, exceeding baselines with lower end-to-end training and sampling time and higher end-to-end throughput. Across ten target HOMO-LUMO gaps, internal ranking retains 30\% of screened candidates and increases the density functional theory-verified hit rate within 0.1 eV from 25.0\% to 52.4\%, while largely preserving novelty and diversity. These results demonstrate fixed-dimensional latent generation with autoregressive decoding as a practical approach to molecular design without prespecifying size.

physics.chem-ph