Vector Flow Imaging in Layered Models With a High Speed of Sound Contrast Using Pulse-Echo Ultrasound and Photoacoustics

Abstract

In this study, we develop vector flow imaging techniques for multi-layered models with a high wavespeed contrast using photoacoustic and ultrasonic imaging. We use refraction-corrected delay-and-sum image reconstruction (RC-DAS), which enforces Snell's law to accurately calculate time delays within each layer. We compare RC-DAS against conventional delay-and-sum for vector flow imaging in benchtop phantoms made of transparent polymethyl methacrylate (PMMA) in a water bath. We study the flow beneath a PMMA layer using two phantoms, where the PMMA layer has different shapes and thicknesses. We image a slow-moving suspension of carbon microspheres (~4 mm/s) using interleaved photoacoustic and multi-angle plane wave ultrasound acquisitions measured with a 7.6 MHz linear ultrasound array. Photoacoustic waves are generated by a 1064 nm wavelength nanosecond-pulsed laser at 50 Hz, and multi-angle plane wave ultrasound data are acquired at 100 Hz for eleven steering angles between $\pm$10$^\circ$. RC-DAS improves the flow speed accuracy, reducing the mean absolute error by 0.41-0.63 mm/s compared to the expected flow profile. The error in direction estimates improves when we use RC-DAS, with the interdecile range reducing by up to 17$^\circ$. This work emphasises the importance of refraction correction for accurate flow measurements in layered media with photoacoustics and ultrasonic imaging. While both imaging modalities can quantify flow in these multi-layered models, the modality best suited for a specific application will depend on the imaging target and flow dynamics. These techniques show promise for biomedical applications such as intraosseous and transcranial blood flow quantification, and in nondestructive testing to monitor fluid motion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Caitlin Smith, Guillaume Renaud, Kasper van Wijk, Jami Shepherd. 2025-12-16. Vector Flow Imaging in Layered Models With a High Speed of Sound Contrast Using Pulse-Echo Ultrasound and Photoacoustics. https://arxiv.org/abs/2512.14933

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph