Search arXivSearch

arXiv · 2512.16789

Evaluation of a large-area double-sided silicon strip detector for quality assurance in ion-beam radiotherapy

Abstract

Designed to provide quality assurance for ion-beam radiotherapy, the prototype fIVI (filtered Interaction Vertex Imaging) Range Monitoring System is a two-layer tracker which employs double-sided strip-segmented silicon detectors. To meet the high demands of a clinical environment, a large sensitive area is required, along with a fast and compact readout. As this device utilizes sensors and readout electronics adapted from particle physics, where the expected energy and count rate differ significantly from radiotherapy, validation was necessary to ensure that these sensors would function effectively at the order 100 MeV/u energies and order MHz count rates expected during clinical irradiation. Tests were conducted using scattered subclinical 19 MeV protons at high intensity, and clinical 207 MeV/u carbon ions at low intensity to independently validate these variables. The detection system is found to operate at rates up to 1.3 MHz, with a negligible fraction of events being affected by pileup. The efficiency of hit reconstruction is high, with a timestamp resolution of 6.25 ns, and a coincidence window of 31.25 ns, as is required for clinical event rates. With these settings, over 90% of particle interactions are able to reconstruct unique hit positions and contribute to track formation. This device is the first system using large-area, high-resolution detectors which meets the demanding count rate requirements associated with clinical radiotherapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Devin Hymers, Sebastian Schroeder, Olga Bertini, Johann Heuser, Joerg Lehnert, Christian Joachim Schmidt, Dennis Mücher. 2025-12-18. Evaluation of a large-area double-sided silicon strip detector for quality assurance in ion-beam radiotherapy. https://arxiv.org/abs/2512.16789

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det