Search arXivSearch

arXiv · 2512.17927

Toward an usage of americium-241 for filter calibration

Abstract

In nuclear safety and environmental studies, it is necessary to measure the activity of aerosols collected on filters. The calibration of these filters' measurement chains currently involves producing a reference filter with a controlled deposit of aerosol marked by a specific radionuclide. In France, commonly used radionuclides include 137 Cs for gamma or beta emitters, 90 Sr/ 90 Y for beta emitters, and 239 Pu for alpha emitters. However, using 239 Pu presents several issues, notably the destruction of the filter required to determine its traceable activity and the associated uncertainties. The challenge of this project is to propose a radionuclide enabling non-destructive, SI-traceable measurement while retaining the reference filter. The proposed radionuclide is 241 Am, which is both alpha and gamma-emitting and allows for precise non-destructive measurements. Reference filters are produced on the IRSN's ICARE test bench with calibrated aerosols tagged with 241 Am. The reference activity of theses filters is measured by gamma spectrometry on CEA/LNHB reference counter. A series of tests confirmed that 241 Am provides accurate activity determination with minimal uncertainty. Consequently, adopting 241 Am can significantly improve the reliability of radioactive contamination monitoring while avoiding practical challenges associated with plutonium.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G. Dougniaux, B. Sabot, S. Pierre, B. Dhieux Lestavel. 2025-12-09. Toward an usage of americium-241 for filter calibration. https://arxiv.org/abs/2512.17927

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det