Search arXivSearch

arXiv · 2512.20543

Precision spectroscopy of the 2S-$n$P transitions in atomic hydrogen

Abstract

Precision spectroscopy of atomic hydrogen is an important way to test bound-state quantum electrodynamics (QED), one of the building blocks of the Standard Model. In its simplest form, such a test consists of the comparison of a measured transition frequency with its QED prediction, which can be calculated with very high precision for the hydrogen atom. However, these calculations require some input in the form of physical constants, such as the Rydberg constant $R_\infty$ and the proton charge radius $r_\mathrm{p}$, both of which are currently determined to a large degree by hydrogen spectroscopy itself. Therefore, the frequency of at least three different transitions needs to be measured in order to test QED. Equivalently, a comparison of the values of $R_\infty$ and $r_\mathrm{p}$ determined from measurements of different transitions constitutes a test of QED. To this end, laser spectroscopy of optical 2S-$n$P transitions has been performed in this work. As these transitions are one-photon transitions, they are affected by a different set of systematic effects than the two-photon transitions on which most other spectroscopic measurements of hydrogen are based. In order to contribute to the test of QED, their transition frequencies must be determined with a relative uncertainty on the order of one part in $10^{12}$, corresponding to approximately 1 kHz in absolute terms. This is in turn approximately a factor of 10000 smaller than the relatively broad natural linewidth of the 2S-$n$P transitions, and a successful measurement requires both a very large experimental signal-to-noise ratio and a detailed theoretical understanding of the line shape of the observed resonance. The 2S-$n$P transitions were probed on a cryogenic beam of hydrogen atoms, which were optically excited to the metastable 2S level. The atomic beam was crossed at right angles with counter-propagating spectroscopy laser beams, which further excited the atoms to the $n$P level. The fluorescence from the subsequent rapid spontaneous decay served as experimental signal. The excitation with two counter-propagating beams led to two Doppler shifts of equal magnitude, but opposite sign, which thus canceled each other out. A velocity-resolved detection was used to determine any residual Doppler shifts, which could be excluded within the measurement uncertainty for both of the measurements discussed below. In a first experiment, the 2S-4P transition was probed. Quantum interference of neighboring atomic resonances produced subtle distortions of the line shape, which were found to be significant because of the very large resolution relative to the linewidth. The line shifts caused by the distortions were directly observed and could be removed by use of a line shape model based on perturbative calculations. With this, the transition frequency was determined with a relative uncertainty of 4 parts in $10^{12}$. In combination with the very precisely measured 1S-2S transition frequency, this allowed the, at the time, most precise determination of $R_\infty$ and $r_\mathrm{p}$ from atomic hydrogen. Moreover, good agreement was found with the much more precise value of $r_\mathrm{p}$ extracted from spectroscopy of muonic hydrogen, which had been in significant disagreement with previous data from (electronic) hydrogen, causing concern about the validity of QED. This result has since been confirmed by other experiments. The 2S-4P measurement is treated in the appendix of this thesis. The 2S-4P measurement, despite its large signal-to-noise ratio, was limited by counting statistics. To improve precision, a transition with a narrower linewidth and an improved experimental signal was necessary. Hence, the study of the 2S-6P transition, which offers a three times smaller natural linewidth, was begun. The atomic beam apparatus was upgraded, resulting in a corresponding decrease of the experimentally observed linewidth, and a close to an order of magnitude larger flux of atoms in the low-velocity tail of the atomic beam. Together with a detector redesign, this led to an up to 16 times larger signal than for the 2S-4P measurement, opening the path to increased precision. The Doppler-shift suppression was also rebuilt to support such precision, including a fiber collimator developed for this purpose, which provides high-quality spectroscopy beams at the new transition wavelength of 410 nm. This enabled a measurement of the 2S-6P transition frequency with a statistical uncertainty of 430 Hz, five times lower than for the 2S-4P measurement and corresponding to a suppression of the Doppler shift by six orders of magnitude. At this level of precision, the light force shift from the diffraction of atoms at the light grating formed by the counter-propagating spectroscopy beams becomes significant. This light force shift was directly observed for the first time for the 2S-$n$P transitions and found to be well-described by a model derived for this purpose. The size of all other systematic effects, except the very precisely known recoil shift, is estimated to be below 500 Hz each. The blind data analysis is ongoing at the time of writing and thus no transition frequencies can yet be given. However, a preliminary analysis suggests a five-fold improvement in the determination of $R_\infty$ and $r_\mathrm{p}$ as compared to the 2S-4P measurement, and a two-fold improvement over the currently most precise determination from atomic hydrogen. This places the uncertainty of the determined value of $r_\mathrm{p}$ within a factor of five of that of the muonic value. The 2S-6P measurement is treated in the main text of this thesis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lothar Maisenbacher. 2025-12-23. Precision spectroscopy of the 2S-$n$P transitions in atomic hydrogen. https://arxiv.org/abs/2512.20543

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Vector Measurements Using Integrated Radio Frequency Atomic Magnetometers

We demonstrate reconstruction of three-dimensional radio-frequency (RF) magnetic-field vectors using a pair of integrated RF atomic magnetometers operated with orthogonal bias-field orientations. A theoretical and experimental analysis identifies a phase-ambiguity dead band that limits reconstruction when the two sensor responses become nearly identical. Measurements performed in an unshielded laboratory environment demonstrate accurate reconstruction of RF magnetic-field orientations and validate the predicted dependence of reconstruction accuracy on signal imbalance. These results establish integrated RF atomic magnetometers as a compact and sensitive platform for directional RF magnetic-field sensing, particularly at low frequencies, and provide a foundation for portable source-localization and field-mapping applications.

physics.atom-ph

Anomalously enhanced lifetimes of low angular momentum Rydberg states in singly charged alkaline-earth metal ions

Trapped ions excited to high-lying electronic states, so-called Rydberg states, open new opportunities for quantum simulation and quantum computing. Generally, the fidelity of quantum coherent operations critically depends on the longevity of Rydberg states. However, scaling laws predict that the lifetimes of Rydberg states in singly charged alkaline-earth metal ions are 16 times shorter, compared to their neutral atom counterparts. Here, we show that this is not generally the case. We report an anomalous lifetime enhancement of certain low angular momentum ionic Rydberg series by factors larger than eight. The anomaly is present at both zero and finite temperature, although it is caused by different mechanisms. At zero temperature, the anomalously enhanced lifetimes are caused by accidental cancellations of the relevant dipole transition matrix elements, while at room temperature the anomaly originates from the enlarged energetic separation of ionic Rydberg levels with respect to neutral-atom levels.

physics.atom-ph

Ytterbium lattice clock with systematic uncertainty of $1.3\times 10^{-18}$ and instability at the $10^{-19}$ level

We report an optical lattice clock based on $^{171}$Yb atoms with a total systematic uncertainty of $1.3\times 10^{-18}$. An in-vacuum buildup cavity was employed to enhance the lattice light power. Differential frequency measurement between two identical clocks facilitates the evaluation of systematic shifts. Synchronous comparison of the two clocks reached a stability level of $2.7\times 10^{-19}$ in an averaging time of 216,000~s. The blackbody radiation (BBR) shield which is placed in vacuum provides a well-characterized BBR environment, enabling an uncertainty contribution of $8.7\times 10^{-19}$ from the BBR Stark shift. Lattice light shifts were measured at different lattice depths $U$, and fitted with a fourth-order polynomial of $U$. The zero-linear-shift frequency $ν_{\mathrm{zero}}$ was determined to be 394 798 260.6(3) MHz. The lattice light shift can be controlled at an uncertainty level of $6.3\times 10^{-19}$ under typical operating conditions. Other systematic shifts have also been evaluated. The two clocks will be used for remote frequency comparisons between Shanghai and Wuhan.

physics.atom-ph