Bi-level Multi-criteria Optimization for Risk-informed Radiotherapy

Abstract

In radiation therapy (RT) treatment planning, multi-criteria optimization (MCO) supports efficient plan selection but is usually solved for population-based dosimetric criteria and ignores patient-specific biological risk, potentially compromising outcomes in high-risk patients. We propose risk-guided MCO, a one-shot method that embeds a clinical risk model into conventional MCO, enabling interactive navigation between dosimetric and biological endpoints. The proposed algorithm uses a special order relation to fuse the classical MCO sandwiching algorithm with bi-level optimization, restricting the Pareto set to plans that achieve improvement in the secondary risk objective for user-defined, acceptable loss in primary clinical objectives. Thus, risk-guided MCO generates risk-optimized counterparts of clinical plans in a single run rather than by sequential or lexicographic planning. To assess the performance, we retrospectively analyzed 19 lung cancer patients treated with RT. The endpoint was the risk of grade 2+ radiation pneumonitis (RP), modeled using bootstrapped stepwise logistics regression with interaction terms, including baseline lung function, smoking history, and dosimetric factors. The risk-guided plans yielded a mean reduction of 8.0% in total lung V20 and 9.5% in right lung V5, translating into an average RP risk reduction of 7.7% (range=0.3%-20.1%), with small changes in target coverage (mean -1.2 D98[%] for CTV) and modest increase in heart dose (mean +1.74 Gy). This study presents the first proof-of-concept for integrating biological risk models directly within multi-criteria RT planning, enabling an interactive balance between established population-wide dose protocols and individualized outcome prediction. Our results demonstrate that the risk-informed MCO can reduce the risk of RP while maintaining target coverage.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mara Schubert, Katrin Teichert, Zhongxing Liao, Thomas Bortfeld, Ali Ajdari. 2026-01-08. Bi-level Multi-criteria Optimization for Risk-informed Radiotherapy. https://doi.org/10.1088/1361-6560%2Fae8122

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph