Finite element (FE) simulations emulating transcatheter pulmonary valve (TPV) system deployment in patient-specific right ventricular outflow tracts (RVOT) assume material properties for the RVOT and adjacent tissues. Sensitivity of the deployment to variation in RVOT material properties is unknown. Moreover, the effect of a transannular patch stiffness and location on simulated TPV deployment has not been explored. A sensitivity analysis on the material properties of a patient-specific RVOT during TPV deployment, modeled as an uncoupled HGO material, was conducted using FEBioUncertainSCI. Further, the effects of a transannular patch during TPV deployment were analyzed by considering two patch locations and four patch stiffnesses. Visualization of results and quantification were performed using custom metrics implemented in SlicerHeart and FEBio. Sensitivity analysis revealed that the shear modulus of the ground matrix (c), fiber modulus (k1), and fiber mean orientation angle (gamma) had the greatest effect on 95th %ile stress, whereas only c had the greatest effect on 95th %ile Lagrangian strain. First-order sensitivity indices contributed the greatest to the total-order sensitivity indices. Simulations using a transannular patch revealed that peak stress and strain were dependent on patch location. As stiffness of the patch increased, greater stress was observed at the interface connecting the patch to the RVOT, and stress in the patch itself increased while strain decreased. The total enclosed volume by the TPV device remained unchanged across all simulated patch cases. This study highlights that while uncertainties in tissue material properties and patch locations may influence functional outcomes, FE simulations provide a reliable framework for evaluating these outcomes in TPVR.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jalaj Maheshwari, Wensi Wu, Christopher N. Zelonis, Steve A. Maas, Kyle Sunderland, Yuval Barak-Corren, Stephen Ching, Patricia Sabin, Andras Lasso, Matthew J. Gillespie, Jeffrey A. Weiss, Matthew A. Jolley. 2026-01-08. Effect of Right Ventricular Outflow Tract Material Properties on Simulated Transcatheter Pulmonary Placement. https://arxiv.org/abs/2601.05410

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph