Search arXivSearch

arXiv · 2601.06028

Leveraging Foundation Models for Calibration-Free c-VEP BCIs

Abstract

Foundation Models (FMs) have surged in popularity over the past five years, with applications spanning fields from computer vision to natural language processing. Brain-Computer Interfaces (BCIs) have also gained momentum due to their potential to support individuals with complex disabilities. Among BCI paradigms, code-modulated Visual Evoked Potentials (c-VEPs) remain relatively understudied, despite offering high information transfer rates and large selection target capacities. However, c-VEP systems require lengthy calibration sessions, limiting their practicality outside of laboratory settings. In this study, we use a FM for the first time to eliminate the need for lengthy calibration in c-VEP BCI systems. We evaluated two approaches: (1) a truly calibration-free approach requiring no subject-specific data, and (2) a limited calibration approach, where we assessed the benefit of incorporating incremental amounts of calibration data. In both cases, a classification head is trained on data from other subjects. For a new subject, no calibration data is required in the calibration-free setup, making the c-VEP system effectively plug-and-play. The proposed method was tested on two c-VEP datasets. For the calibration-free approach, the average accuracy on the first dataset (n = 17) was 68.8% +/- 17.6%, comparable to the full-calibration performance reported in the original study (66.2% +/- 13.8%), which required approximately 11 minutes of calibration. On the second dataset (n = 12), the calibration-free accuracy was 71.8% +/- 20.2%, versus 93.7% +/- 5.5% from the original study, which required around 3.5 minutes. A limited-calibration approach using only 20% of the subject's data (approximately 43 seconds) yielded 92% +/- 5.2% accuracy. These results indicate that our FM-based approach can effectively eliminate or significantly reduce the need for lengthy calibration in c-VEP BCIs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mohammadreza Behboodi, Eli Kinney-Lang, Ali Etemad, Adam Kirton, Hatem Abou-Zeid. 2025-11-04. Leveraging Foundation Models for Calibration-Free c-VEP BCIs. https://doi.org/10.1109/smc58881.2025.11342650

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TrialCompass: Visual Analytics for Enhancing the Eligibility Criteria Design of Clinical Trials

Eligibility criteria play a critical role in clinical trials by determining the target patient population, which significantly influences the outcomes of medical interventions. However, current approaches for designing eligibility criteria have limitations to support interactive exploration of the large space of eligibility criteria. They also ignore incorporating detailed characteristics from the original electronic health record (EHR) data for criteria refinement. To address these limitations, we proposed TrialCompass, a visual analytics system integrating a novel workflow, which can empower clinicians to iteratively explore the vast space of eligibility criteria through knowledge-driven and outcome-driven approaches. TrialCompass supports history-tracking to help clinicians trace the evolution of their adjustments and decisions when exploring various forms of data (i.e., eligibility criteria, outcome metrics, and detailed characteristics of original EHR data) through these two approaches. This feature can help clinicians comprehend the impact of eligibility criteria on outcome metrics and patient characteristics, which facilitates systematic refinement of eligibility criteria. Using a real-world dataset, we demonstrated the effectiveness of TrialCompass in providing insights into designing eligibility criteria for septic shock and sepsis-associated acute kidney injury. We also discussed the research prospects of applying visual analytics to clinical trials.

cs.HC

PRIMMDebug: Teaching Secondary School Students a Reflective Approach to Debugging

Debugging is a challenging and infuriating experience for many secondary school students learning their first text-based programming language. One frequent problem is the lack of reflection in students' debugging strategies, which makes error resolution unlikely and teacher reliance common. Tools that encourage more reflective and teacher-independent debugging may foster more success with fixing errors, but are lacking. This paper presents PRIMMDebug, an approach for teaching the debugging process to secondary school students. PRIMMDebug consists of an online tool that takes students through the steps of a pedagogical process based on PRIMM, a framework for teaching programming. The tool encourages written articulation throughout the debugging process and limits students' ability to run and edit code at certain stages. A classroom study with PRIMMDebug found a general reluctance among students to engage with the reflection it promotes, despite teachers appreciating this emphasis on reflection. We end by suggesting three considerations for future pedagogical debugging research and tooling: balance structure and flexibility, teach shorter debugging heuristics, and use tooling early on in students' programming journey.

cs.HC

Mirror Skin: In Situ Visualization of Robot Touch Intent on Robotic Skin

Effective communication of robot touch intent is essential for safe and predictable physical human-robot interaction. While intent communication has been widely studied, existing approaches lack the spatial specificity and semantic depth necessary to efficiently convey robot touch intent. We present Mirror Skin, a cephalopod inspired concept that mirrors in-situ visual representations of a human's body parts onto the corresponding robot's touch region to communicate who shall initiate touch, where it will occur, and when it is imminent. We informed the design of Mirror Skin through a structured design exploration with experts and demonstrate the real-world feasibility of Mirror Skin with a proof-of-concept prototype. User studies in VR and with the physical prototype showed that Mirror Skin significantly improves accuracy and response times for interpreting touch intent and improves the user experience during physical human-robot interactions.

cs.HC