Search arXivSearch

arXiv · 2601.19246

Magnetic Resonance Simulation of Effective Transverse Relaxation (T2*)

Abstract

Purpose: To simulate effective transverse relaxation ($T_2^*$) as a part of MR simulation. $T_2^*$ consists of reversible ($T_2^{\prime}$) and irreversible ($T_2$) components. Whereas simulations of $T_2$ are easy, $T_2^{\prime}$ is not easily simulated if only magnetizations of individual isochromats are simulated. Theory and Methods: Efficient methods for simulating $T_2^{\prime}$ were proposed. To approximate the Lorentzian function of $T_2^{\prime}$ realistically, conventional simulators require 100+ isochromats. This approximation can be avoided by utilizing a linear phase model for simulating an entire Lorentzian function directly. To represent the linear phase model, the partial derivatives of the magnetizations with respect to the frequency axis were also simulated. To accelerate the simulations with these partial derivatives, the proposed methods introduced two techniques: analytic solutions, and combined transitions. For understanding the fundamental mechanism of the proposed method, a simple one-isochromat simulation was performed. For evaluating realistic cases, several pulse sequences were simulated using two phantoms with and without $T_2^{\prime}$ simulations. Results: The one-isochromat simulation demonstrated that $T_2^{\prime}$ simulations were possible. In the realistic cases, $T_2^{\prime}$ was recovered as expected without using 100+ isochromats for each point. The computational times with $T_2^{\prime}$ simulations were only 2.0 to 2.7 times longer than those without $T_2^{\prime}$ simulations. When the above-mentioned two techniques were utilized, the analytic solutions accelerated 19 times, and the combined transitions accelerated up to 17 times. Conclusion: Both theory and results showed that the proposed methods simulated $T_2^{\prime}$ efficiently by utilizing a linear model with a Lorentzian function, analytic solutions, and combined transitions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hidenori Takeshima. 2026-01-27. Magnetic Resonance Simulation of Effective Transverse Relaxation (T2*). https://arxiv.org/abs/2601.19246

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Dipole-lets: a new multiscale decomposition for MR phase and quantitative susceptibility mapping

Nondipolar phase contributions can generate severe streaking artifacts during quantitative susceptibility mapping (QSM) inversion. We propose Dipole-lets, a dipole-adapted multiscale decomposition designed to identify phase components associated with streaking artifacts before and during susceptibility inversion. Dipole- lets combine an undecimated radial decomposition with an angular partition based on proximity to the magic cone. The resulting coefficients emphasize phase components near the magic cone, where nondipolar contributions may become relatively prominent. This information was incorporated into QSM reconstruction through a data- driven fidelity weight and a Dipole-let-based regularizer that models an additional nondipolar phase component. The methods were evaluated using modified simulated QSM data and an in vivo dataset. The data-driven weighting reduced streaking artifacts while preserving anatomical detail and improved quantitative reconstruction metrics compared with magnitude-weighted TV. The Dipole-let regularizer achieved streaking suppression comparable to L1-QSM and lower reconstruction error in the modified simulated dataset. In vivo experiments further demonstrated the applicability of the proposed approach to data with strong susceptibility-induced phase perturbations. Dipole-lets provide a multiscale representation for characterizing phase components associated with streaking artifacts and incorporating this information into QSM reconstruction, reducing streaking while preserving relevant susceptibility structures, and providing a flexible basis for future QSM reconstruction methods.

eess.IV

MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical Imaging

In the field of medical imaging, AI-assisted techniques such as object detection, segmentation, and classification are widely employed to alleviate the workload of physicians and doctors. However, single-task models are predominantly used, overlooking the shared information across tasks. This oversight leads to inefficiencies in real-life applications. In this work, we propose MTMed3D, a novel end-to-end Multi-task Transformer-based model to address the limitations of single-task models by jointly performing 3D detection, segmentation, and classification in medical imaging. Our model uses a Transformer as the shared encoder to generate multi-scale features, followed by CNN-based task-specific decoders. The proposed framework was evaluated on the BraTS 2018 and 2019 datasets, achieving promising results across all three tasks, especially in detection, where our method achieves better results than prior works. Additionally, we compare our multi-task model with equivalent single-task variants trained separately. Our multi-task model significantly reduces computational costs and achieves faster inference speed while maintaining comparable performance to the single-task models, highlighting its efficiency advantage. To the best of our knowledge, this is the first work to leverage Transformers for multi-task learning that simultaneously covers detection, segmentation, and classification tasks in 3D medical imaging, presenting its potential to enhance diagnostic processes. The code is available at https://github.com/fanlimua/MTMed3D.git.

eess.IV

VideoPulse: Neonatal heart rate and peripheral capillary oxygen saturation (SpO2) estimation from contact free video

Remote photoplethysmography (rPPG) enables contact free monitoring of vital signs and is especially valuable for neonates, since conventional methods often require sustained skin contact with adhesive probes that can irritate fragile skin and increase infection control burden. We present VideoPulse, a neonatal dataset and an end to end pipeline that estimates neonatal heart rate and peripheral capillary oxygen saturation (SpO2) from facial video. VideoPulse contains 157 recordings totaling 2.6 hours from 52 neonates with diverse face orientations. Our pipeline performs face alignment and artifact aware supervision using denoised pulse oximeter signals, then applies 3D CNN backbones for heart rate and SpO2 regression with label distribution smoothing and weighted regression for SpO2. Predictions are produced in 2 second windows. On the NBHR neonatal dataset, we obtain heart rate MAE 2.97 bpm using 2 second windows (2.80 bpm at 6 second windows) and SpO2 MAE 1.69 percent. Under cross dataset evaluation, the NBHR trained heart rate model attains 5.34 bpm MAE on VideoPulse, and fine tuning an NBHR pretrained SpO2 model on VideoPulse yields MAE 1.68 percent. These results indicate that short unaligned neonatal video segments can support accurate heart rate and SpO2 estimation, enabling low cost non invasive monitoring in neonatal intensive care.

eess.IV