Implications of temporal sampling in voltage imaging microscopy

Abstract

Significance: Voltage imaging microscopy has emerged as a powerful tool to investigate neural activity both in vivo and in vitro. Various imaging approaches have been developed, including point-scanning, line-scanning and wide-field microscopes, however the effects of their different temporal sampling methods on signal fidelity have not yet been fully investigated. Aim: To provide an analysis of the inherent advantages and disadvantages of temporal sampling in scanning and wide-field microscopes and their effect on the fidelity of voltage spike detection. Approach: We develop a mathematical framework based on a mixture of analytical modeling and computer simulations with Monte-Carlo approaches. Results: Scanning microscopes outperform wide-field microscopes in low signal-to-noise conditions and when only a small subset of spikes needs to be detected. Wide-field microscopes outperform scanning microscopes when the measurement is temporally undersampled and a large fraction of the spikes needs to be detected. Both modalities converge in performance as sampling increases and the frame rate reaches the decay rate of the voltage indicator. Conclusions: Our work provides guidance for the selection of optimal temporal sampling parameters for voltage imaging. Most importantly it advises against using scanning voltage imaging microscopes at frame rates below 500 Hz.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jakub Czuchnowski, Jerome Mertz. 2026-01-28. Implications of temporal sampling in voltage imaging microscopy. https://arxiv.org/abs/2601.20236

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Rubidium referenced Kerr comb with cavity phase matching

Phase matching is a fundamental problem in nonlinear optics that is normally constrained by material dispersion. The limited operation wavelengths within phase matching window limits the application, including the precise metrology using Kerr combs. Demanding applications like compact optical clock and astronomical spectroscopy requires atomic reference around 800 nm, where the natural phase matching is challenging. Here we revisit the concept of cavity phase matching (CPM), and fully reveal its advantage to engineer artificial phase matching beyond material dispersion. With the access of CPM condition in a monolithic high-Q fiber Fabry-Pérot resonator featuring a macroscopic cavity length, we achieve low noise Kerr comb generation around 800 nm, within the power budget of a single-mode laser diode. Inside a pump-integrated package of 19 cm3, low phase noise of -125 dBc/Hz at 100 kHz offset frequency is achieved for a 10.1 GHz repetition rate. Most importantly, the generated Kerr comb has been directly referenced to rubidium atomic transition for long-term stable operation. This result not only opens a new way for Kerr comb generation at arbitrary wavelengths, but also can be generalized to any other nonlinear optical frequency conversion application.

physics.optics

Mid-infrared reconfiguration of population flow in lanthanide nanocrystals

Converting mid-infrared (MIR) radiation to visible or near-infrared wavelengths is essential for imaging and sensing, yet achieving sensitive, low-power, and scalable detection remains challenging. Lanthanide nanocrystals provide an alternative through ratiometric luminescence but are typically constrained by Boltzmann statistics, which tie population distributions to lattice temperature and limit signal contrast. Here we show that MIR irradiation rebalances dissipative relaxation pathways, driving lanthanide emitters into a non-Boltzmann steady state that enables non-thermal control of population distributions. This allows emission behaviors inaccessible under thermal equilibrium. We exploit this regime to achieve linear MIR detection with respect to MIR power across 6.8 to 8.6 micrometers. The ratiometric response is intrinsically independent of the pump power, enabling operation at an ultralow excitation power of 10 uW, several orders of magnitude lower than conventional approaches. Using standard silicon photodetectors, we then demonstrate room-temperature MIR imaging with detection limits approaching 4 nW um-2. Our results establish lanthanide nanoparticles as an efficient platform for MIR conversion and sensing in nanophotonic systems.

physics.optics

Intracavity THz generation using a thin lithium niobate plate in a compact Kerr-lens mode-locked Yb:CALGO bulk oscillator

We demonstrate intracavity terahertz (THz) generation via optical rectification in a 50-m-thick lithium niobate crystal placed inside a compact diode-pumped Kerr-lens mode-locked (KLM) Yb:CALGO bulk oscillator. The oscillator operates at a repetition rate of 85 MHz and delivers 83-fs pulses with up to 71 W of average intracavity power, obtained with only 21.4 W of low-cost multimode diode pump power. We generate single-cycle THz pulses with a spectrum extending up to 3 THz, detected by electro-optic sampling with 60 dB dynamic range within 156 s of measurement time (313 averaged traces) and up to 120 W of THz average power. This work combines the high damage threshold, power-handling capability, and cost-effectiveness of thin LN plates with simplicity, compactness, and low-cost multimode diode-pumped solid-state bulk lasers, offering an attractive alternative for high-repetition-rate THz time-domain spectroscopy systems.

physics.optics