Search arXivSearch

arXiv · 2602.03710

Quantum Computing for Electronic Circular Dichroism Spectrum Prediction of Chiral Molecules

Abstract

Electronic circular dichroism (ECD) spectroscopy captures the chiroptical response of molecules, enabling absolute configuration assignment that is vital for enantioselective synthesis and drug design. The practical use of ECD spectra in predictive modeling remains restricted, as existing approaches offer limited confidence for chiral discrimination. By contrast, theoretical ECD calculations demand substantial computational effort rooted in electronic structure theory, which constrains their scalability to larger chemically diverse molecules. These limitations underscore the need for computational approaches that retain first principles physical rigor while enabling efficient and scalable prediction. Motivated by recent advances in quantum algorithms for chemistry, we introduce a variational quantum framework combined with the quantum equation of motion formalism to compute molecular properties and predict ECD spectra, implemented within a multi GPU or QPU accelerated hybrid quantum/classical workflow. We demonstrate its efficient applicability on 12 clinically relevant chiral drug molecules accessing expanded active spaces. The proposed framework is assessed by comparison with established classical wavefunction based methods, employing Coupled Cluster Singles and Doubles (CCSD) for ground-state energy benchmarks and Complete Active Space Configuration Interaction (CASCI) as the reference method for excited state energies and chiroptical properties within the same active orbital space. Notably, the quantum computed ECD spectra, obtained from chemically relevant active spaces mapped onto quantum circuits of approximately 20 to 24 qubits, exhibit near quantitative agreement with classical reference calculations, accurately reproducing spectral line shapes, Cotton effect signs, and relative peak intensities.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Amandeep Singh Bhatia, Sabre Kais. 2026-02-03. Quantum Computing for Electronic Circular Dichroism Spectrum Prediction of Chiral Molecules. https://arxiv.org/abs/2602.03710

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Iteratively decoded magic state distillation

We present numerical simulation results for the 7-to-1 and 15-to-1 state distillation circuits, constructed using transversal CNOTs acting on multiple surface code patches. The distillation circuits are decoded iteratively using the method outlined in [arXiv:2407.20976]. We show that, with a re-configurable qubit architecture, we can perform fast magic state distillation in $\sim\mathcal{O}(1)$ code cycles. We confirm that both circuits suppress an injected input logical error rate $p$ to $\mathcal{O}(p^3)$ in the presence of additional circuit-level noise. This is done with two types of stabiliser proxies, distilling logical $|-\rangle$ and $|Y\rangle$ states, the latter is the intended state of the 7-to-1 circuit while a stabiliser-proxy for the 15-to-1 circuit. We then also provide numerical evidences for actual $|T\rangle$ state distillation using the 15-to-1 circuit with a faulty-$T$ measurement, leveraging recent near-Clifford simulation tools. Finally, we outline how ZX-calculus and Pauli webs can be used to benchmark stabiliser proxies for these distillation circuits.

quant-ph

Enhanced measurements on quantum computers via the simultaneous probing of non-commuting Pauli operators

Measuring the state of quantum computers is a highly non-trivial task, with implications for virtually all quantum algorithms. A promising avenue is multi-copy schemes, where identical copies of a quantum state are measured jointly so that all Pauli operators within the considered observable can be simultaneously assessed. Here, we present a first implementation of such a two-copy scheme in a measurement protocol. Based on Bayesian statistics, it accurately estimates not only the average of the desired observable but also the error en route. This enables an adaptive shot-allocation algorithm that preferentially samples the most uncertain Pauli terms. In regimes with many non-commuting Pauli operators, this ``double'' scheme can outperform the state-of-the-art measurement protocol in minimizing total shots for a given precision. We also numerically confirm the finding in previous theoretical works that the two-copy scheme incurs an overhead due to the square-root relationship between the variance of measured quantities and the number of measurement shots.

quant-ph

Thermodynamics of a phaseonium-driven optomechanical Otto engine

We study an optomechanical Otto engine whose working medium is a single-mode cavity driven by beams of coherently prepared three-level phaseonium atoms. The atoms are not thermal reservoirs in the Gibbs sense; rather, their populations and ground-state coherence set the detailed-balance ratio of the cavity collision map, so that the field relaxes to a Gibbs state at an operational apparent temperature. We combine the finite-time collision-model dynamics with radiation-pressure work extraction and compare three reservoir preparations: a thermal reference at the same apparent temperatures, an incoherent atomic beam with the same populations, and the coherent phaseonium beam. We show that the phaseonium isochore charges the cavity passively: the cavity ergotropy and energy-basis coherence remain zero up to numerical precision, while the state converges to the Gibbs fixed point selected by the apparent detailed balance. We further estimate lower bounds on the cost of preparing the atomic populations and coherence, showing that the relevant advantage of phaseonium is a resource-preparation tradeoff rather than a cost-free enhancement over a thermal bath at the same temperature. Finally, we assess the finite-time performance of a two-cavity cascade with additive mechanical work accounting. Over the investigated coherence-phase range, the cascade produces approximately $47\%$--$52\%$ more power than the single-cavity engine while requiring only $65\%$--$68\%$ of the hot and cold phaseonium atoms needed by two independent engines, resulting in a $9\%$--$15\%$ enhancement of power per injected atom over a complete cycle.

quant-ph