Search arXivSearch

arXiv · 2602.05244

Relativistic quintuple-zeta basis sets for the p block

Abstract

Relativistic quintuple-zeta basis sets for the p elements are presented. The basis sets for the occupied spinors were optimized at the Dirac-Coulomb self-consistent field (SCF) level on the ground configurations. Valence and core correlating functions were optimized in multireference SDCI calculations on the ground configuration. Diffuse functions optimized on the anion (or derived from neighboring elements for group 18) are also provided. Basic atomic and molecular properties were used to test the newly developed basis sets. A smooth convergence to the basis set limit is observed with increased basis set quality from the previously available double-zeta, triple-zeta, and quadruple-zeta basis sets to the newly developed quintuple-zeta basis sets for the calculated molecular bond lengths and dissociation energies and for atomic ionization potentials and electron affinities. Use of these basis sets in combination with state-of-the-art approaches for treatment of relativity and correlation will allow significantly increased accuracy in calculations on the heavy elements and their compounds. The basis sets are available at https://doi.org/10.5281/zenodo.18351835.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Marten L. Reitsma, Eifion H. Prinsen, Johan D. Polet, Anastasia Borschevsky, Kenneth G. Dyall. 2026-02-05. Relativistic quintuple-zeta basis sets for the p block. https://doi.org/10.1063/5.0311040

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Vector Measurements Using Integrated Radio Frequency Atomic Magnetometers

We demonstrate reconstruction of three-dimensional radio-frequency (RF) magnetic-field vectors using a pair of integrated RF atomic magnetometers operated with orthogonal bias-field orientations. A theoretical and experimental analysis identifies a phase-ambiguity dead band that limits reconstruction when the two sensor responses become nearly identical. Measurements performed in an unshielded laboratory environment demonstrate accurate reconstruction of RF magnetic-field orientations and validate the predicted dependence of reconstruction accuracy on signal imbalance. These results establish integrated RF atomic magnetometers as a compact and sensitive platform for directional RF magnetic-field sensing, particularly at low frequencies, and provide a foundation for portable source-localization and field-mapping applications.

physics.atom-ph

Anomalously enhanced lifetimes of low angular momentum Rydberg states in singly charged alkaline-earth metal ions

Trapped ions excited to high-lying electronic states, so-called Rydberg states, open new opportunities for quantum simulation and quantum computing. Generally, the fidelity of quantum coherent operations critically depends on the longevity of Rydberg states. However, scaling laws predict that the lifetimes of Rydberg states in singly charged alkaline-earth metal ions are 16 times shorter, compared to their neutral atom counterparts. Here, we show that this is not generally the case. We report an anomalous lifetime enhancement of certain low angular momentum ionic Rydberg series by factors larger than eight. The anomaly is present at both zero and finite temperature, although it is caused by different mechanisms. At zero temperature, the anomalously enhanced lifetimes are caused by accidental cancellations of the relevant dipole transition matrix elements, while at room temperature the anomaly originates from the enlarged energetic separation of ionic Rydberg levels with respect to neutral-atom levels.

physics.atom-ph

Ytterbium lattice clock with systematic uncertainty of $1.3\times 10^{-18}$ and instability at the $10^{-19}$ level

We report an optical lattice clock based on $^{171}$Yb atoms with a total systematic uncertainty of $1.3\times 10^{-18}$. An in-vacuum buildup cavity was employed to enhance the lattice light power. Differential frequency measurement between two identical clocks facilitates the evaluation of systematic shifts. Synchronous comparison of the two clocks reached a stability level of $2.7\times 10^{-19}$ in an averaging time of 216,000~s. The blackbody radiation (BBR) shield which is placed in vacuum provides a well-characterized BBR environment, enabling an uncertainty contribution of $8.7\times 10^{-19}$ from the BBR Stark shift. Lattice light shifts were measured at different lattice depths $U$, and fitted with a fourth-order polynomial of $U$. The zero-linear-shift frequency $ν_{\mathrm{zero}}$ was determined to be 394 798 260.6(3) MHz. The lattice light shift can be controlled at an uncertainty level of $6.3\times 10^{-19}$ under typical operating conditions. Other systematic shifts have also been evaluated. The two clocks will be used for remote frequency comparisons between Shanghai and Wuhan.

physics.atom-ph