Search arXivSearch

arXiv · 2602.08580

retinalysis-vascx: An explainable software toolbox for the extraction of retinal vascular biomarkers

Abstract

Automatic extraction of retinal vascular biomarkers from color fundus images (CFI) is crucial for large-scale studies of the retinal vasculature. We present VascX, an open-source Python toolbox that extracts biomarkers from CFI artery-vein segmentations. VascX starts from vessel segmentation masks, extracts their skeletons, builds undirected and directed vessel graphs, and resolves vessel segments into longer vessels. A comprehensive set of biomarkers is derived, including vascular density, central retinal equivalents (CREs), and tortuosity. Spatially localized biomarkers may be calculated over grids placed relative to the fovea and optic disc. VascX is released via GitHub and PyPI with comprehensive documentation and examples. Our test-retest reproducibility analysis on repeat imaging of the same eye by different devices shows that most VascX biomarkers have moderate to excellent agreement (ICC > 0.5), with important differences in the level of robustness of different biomarkers. Our analyses of biomarker sensitivity to image perturbations and heuristic parameter values support these differences and further characterize VascX biomarkers. Ultimately, VascX provides an explainable and easily modifiable feature-extraction toolbox that complements segmentation to produce reliable retinal vascular biomarkers. Our graph-based biomarker computation stages support reproducible, region-aware measurements suited for large-scale clinical and epidemiological research. By enabling easy extraction of existing biomarkers and rapid experimentation with new ones, VascX supports oculomics research. Its robustness and computational efficiency facilitate scalable deployment in large databases, while open-source distribution lowers barriers to adoption for ophthalmic researchers and clinicians.

Explore related subjects

Keep this discovery

BibTeXRIS

Jose D. Vargas Quiros, Michael J. Beyeler, Sofia Ortin Vela, EyeNED Reading Center, Sven Bergmann, Caroline C. W. Klaver, Bart Liefers, VascX Research Consortium. 2026-08-31. retinalysis-vascx: An explainable software toolbox for the extraction of retinal vascular biomarkers. https://arxiv.org/abs/2602.08580

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related papers

Intelligent Software System for Low-Cost, Brightfield Segmentation: Algorithmic Implementation for Cytometric Auto-Analysis

Bright-field microscopy, a cost-effective solution for live-cell culture, is often the only resource available, along with standard CPUs, for many low-budget labs. The inherent challenges of bright-field images -- their noisiness, low contrast, and dynamic morphology -- coupled with a lack of GPU resources and complex software interfaces, hinder the desired research output. This article presents a novel microscopy image analysis framework designed for low-budget labs equipped with a standard CPU desktop. The Python-based program enables cytometric analysis of live, unstained cells in culture through an advanced computer vision and machine learning pipeline. Crucially, the framework operates on label-free data, requiring no manually annotated training data or training phase. It is accessible via a user-friendly, cross-platform GUI that requires no programming skills, while also providing a scripting interface for programmatic control and integration by developers. The end-to-end workflow performs semantic and instance segmentation, feature extraction, analysis, evaluation, and automated report generation. Its modular architecture supports easy maintenance and flexible integration while supporting both single-image and batch processing. Validated on several unstained cell types from the public dataset of livecells, the framework demonstrates superior accuracy and reproducibility compared to contemporary tools like Cellpose and StarDist. Its competitive segmentation speed on a CPU-based platform highlights its significant potential for basic research and clinical applications -- particularly in cell transplantation for personalised medicine and muscle regeneration therapies. The access to the application is available for reproducibility

q-bio.QM

JUMP-lite: Compact, reproducible benchmarking of cell representations

Image-based profiling captures rich phenotypic signatures for drug discovery and functional genomics. Large public datasets like JUMP Cell Painting now provide millions of images for systematic study. However, JUMP alone occupies 115 TB, and fragmented evaluation practices make systematic comparisons of representation methods impractical for many researchers. Here we present Nahual, an open-source framework for reproducible model deployment, and JUMP-lite, a 92.0 GB subset of JUMP that is approximately 1,250-fold smaller, selected to cover genetic modalities and compound annotations and reduced via lossy JPEG XL compression. Using these resources, we benchmark five representation methods, including classical features (CellProfiler) and deep learning models (MorphEM, OpenPhenom, SubCell, DINOv2). Moderate compression broadly retains signal relative to uncompressed images. Standardized phenotypic activity and consistency metrics reveal meaningful performance differences across methods. Together, JUMP-lite and Nahual provide a foundation for accessible, reproducible benchmarking of image-based cell representations.

q-bio.QM

Reconstruction-Aware Cryo-EM Particle Picking

Cryo-electron microscopy (cryo-EM) determines the structures of proteins and macromolecular assemblies at near-atomic resolution, and the final 3D reconstruction depends on extracting a clean particle stack from noisy micrographs. This extraction decomposes into three sub-tasks, namely particle picking, contamination removal, and 2D class selection. Each of them, however, is trained and evaluated in isolation, and none is optimized for the reconstruction. We instead integrate the three sub-tasks into a single pipeline posed against downstream reconstruction quality. We instantiate the pipeline with a state-of-the-art component for each sub-task, CryoTransformer picking permissively, MicrographCleaner masking contamination, and CryoSift selecting 2D classes by a continuous quality score, and close the loop with a fine-tuning step that returns the surviving particles to the picker. The pipeline achieves a better 3D resolution than every picker we compare. We also show that the best 2D F1 is not the best resolution, so particle selection is better treated as one reconstruction-aware pipeline judged by the map it delivers.

q-bio.BM