Search arXivSearch

arXiv · 2602.17475

Small LLMs for Medical NLP: a Systematic Analysis of Few-Shot, Constraint Decoding, Fine-Tuning and Continual Pre-Training in Italian

Abstract

Large Language Models (LLMs) consistently excel in diverse medical Natural Language Processing (NLP) tasks, yet their substantial computational requirements often limit deployment in real-world healthcare settings. In this work, we investigate whether "small" LLMs (around one billion parameters) can effectively perform medical tasks while maintaining competitive accuracy. We evaluate models from three major families-Llama-3, Gemma-3, and Qwen3-across 20 clinical NLP tasks among Named Entity Recognition, Relation Extraction, Case Report Form Filling, Question Answering, and Argument Mining. We systematically compare a range of adaptation strategies, both at inference time (few-shot prompting, constraint decoding) and at training time (supervised fine-tuning, continual pretraining). Fine-tuning emerges as the most effective approach, while the combination of few-shot prompting and constraint decoding offers strong lower-resource alternatives. Our results show that small LLMs can match or even surpass larger baselines, with our best configuration based on Qwen3-1.7B achieving an average score +9.2 points higher than Qwen3-32B. We release a comprehensive collection of all the publicly available Italian medical datasets for NLP tasks, together with our top-performing models. Furthermore, we release an Italian dataset of 126M words from the Emergency Department of an Italian Hospital, and 175M words from various sources that we used for continual pre-training.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pietro Ferrazzi, Mattia Franzin, Alberto Lavelli, Bernardo Magnini. 2026-02-19. Small LLMs for Medical NLP: a Systematic Analysis of Few-Shot, Constraint Decoding, Fine-Tuning and Continual Pre-Training in Italian. https://arxiv.org/abs/2602.17475

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

SafetyFlow: An Agent-Flow System for Automated LLM Safety Benchmarking

The rapid proliferation of large language models (LLMs) has intensified the requirement for reliable safety evaluation to uncover model vulnerabilities. To this end, numerous LLM safety evaluation benchmarks are proposed. However, existing benchmarks generally rely on labor-intensive manual curation, which causes excessive time and resource consumption. They also exhibit significant redundancy and limited difficulty. To alleviate these problems, we introduce SafetyFlow, the first agent-flow system designed to automate the construction of LLM safety benchmarks. SafetyFlow can automatically build a comprehensive safety benchmark in only four days without any human intervention by orchestrating seven specialized agents, significantly reducing time and resource cost. Equipped with versatile tools, the agents of SafetyFlow ensure process and cost controllability while integrating human expertise into the automatic pipeline. The final constructed dataset, SafetyFlowBench, contains 23,446 queries with low redundancy and strong discriminative power. Our contribution includes the first fully automated benchmarking pipeline and a comprehensive safety benchmark. We evaluate the safety of 49 advanced LLMs on our dataset and conduct extensive experiments to validate our efficacy and efficiency.

cs.CL

Geometric Uncertainty for Detecting and Correcting Hallucinations in LLMs

Large language models are known to hallucinate, generating linguistically plausible but incorrect answers to questions. Uncertainty quantification has been proposed as a strategy to detect such behaviour, but existing methods lack a unified framework to assess reliability at both the prompt and answer level. We introduce a geometric framework which quantifies language model uncertainty at both levels by explicitly modelling a prompt-conditioned semantic distribution in answer embedding space. Our approach is black-box and sampling-based; we generate multiple answers per prompt, and use archetypal analysis to estimate a geometric support for the answer distribution. At the prompt level, we approximate the distribution entropy to quantify uncertainty; for each individual answer, we then use notions of atypicality to assess its reliability relative to the batch. We employ our framework to not only detect hallucinations but correct them, by selecting the batch example deemed most reliable. Experiments show that our framework performs comparably to or better than prior methods on short form question-answering datasets, and achieves superior results on medical datasets where hallucinations carry particularly critical risks. Beyond pure performance, we suggest the theoretical grounding of our work provides support for semantic distributions as useful objects of study for language model uncertainty.

cs.CL

Calibrated Confidence Expression for Radiology Report Generation

Safe deployment of Large Vision-Language Models (LVLMs) in radiology report generation requires not only accurate predictions but also clinically interpretable indicators of when outputs should be thoroughly reviewed, enabling selective radiologist verification and reducing the risk of hallucinated findings influencing clinical decisions. One intuitive approach to this is verbalized confidence, where the model explicitly states its certainty. However, current state-of-the-art language models are often overconfident, and research on calibration in multimodal settings such as radiology report generation is limited. To address this gap, we introduce ConRad (Confidence Calibration for Radiology Reports), a reinforcement learning framework for fine-tuning medical LVLMs to produce calibrated verbalized confidence estimates alongside radiology reports. We study two settings: a single report-level confidence score and a sentence-level variant assigning a confidence to each claim. Both are trained using the GRPO algorithm with reward functions based on the logarithmic scoring rule, which incentivizes truthful self-assessment by penalizing miscalibration and guarantees optimal calibration under reward maximization. Experimentally, ConRad substantially improves calibration and outperforms competing methods. In a clinical evaluation we show that ConRad's report level scores are well aligned with clinicians' judgment. By highlighting full reports or low-confidence statements for targeted review, ConRad can support safer clinical integration of AI-assistance for report generation.

cs.CL