Search arXivSearch

arXiv · 2603.07687

Characterization of the Low Energy Excess using a NUCLEUS Al$_{2}$O$_{3}$ detector

Abstract

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $(-0.59 \pm 0.06)$, when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H. Abele, G. Angloher, B. Arnold, M. Atzori Corona, A. Bento, E. Bossio, F. Buchsteiner, J. Burkhart, F. Cappella, M. Cappelli, N. Casali, R. Cerulli, A. Cruciani, G. Del Castello, M. del Gallo Roccagiovine, S. Dorer, A. Erhart, M. Friedl, S. Fichtinger, V. M. Ghete, M. Giammei, C. Goupy, J. Hakenmüller, D. Hauff, F. Jeanneau, E. Jericha, M. Kaznacheeva, H. Kluck, A. Langenkämper, T. Lasserre, D. Lhuillier, M. Mancuso, R. Martin, B. Mauri, A. Mazzolari, L. McCallin, H. Neyrial, C. Nones, L. Oberauer, L. Peters, F. Petricca, W. Potzel, F. Pröbst, F. Pucci, F. Reindl, M. Romagnoni, J. Rothe, N. Schermer, J. Schieck, S. Schönert, C. Schwertner, L. Scola, G. Soum-Sidikov, L. Stodolsky, A. Schröder, R. Strauss, R. Thalmeier, C. Tomei, L. Valla, M. Vignati, M. Vivier, A. Wallach, P. Wasser, A. Wex, L. Wienke. 2026-08-27. Characterization of the Low Energy Excess using a NUCLEUS Al$_{2}$O$_{3}$ detector. https://doi.org/10.1140/epjc%2Fs10052-026-15950-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det