Search arXiv⌕ Search

arXiv · 2603.19993

MedSPOT: A Workflow-Aware Sequential Grounding Benchmark for Clinical GUI

Abstract

Despite the rapid progress of Multimodal Large Language Models (MLLMs), their ability to perform reliable visual grounding in high-stakes clinical software environments remains underexplored. Existing GUI benchmarks largely focus on isolated, single-step grounding queries, overlooking the sequential, workflow-driven reasoning required in real-world medical interfaces, where tasks evolve across independent steps and dynamic interface states. We introduce MedSPOT, a workflow-aware sequential grounding benchmark for clinical GUI environments. Unlike prior benchmarks that treat grounding as a standalone prediction task, MedSPOT models procedural interaction as a sequence of structured spatial decisions. The benchmark comprises 216 task-driven videos with 597 annotated keyframes, in which each task consists of 2 to 3 interdependent grounding steps within realistic medical workflows. This design captures interface hierarchies, contextual dependencies, and fine-grained spatial precision under evolving conditions. To evaluate procedural robustness, we propose a strict sequential evaluation protocol that terminates task assessment upon the first incorrect grounding prediction, explicitly measuring error propagation in multi-step workflows. We further introduce a comprehensive failure taxonomy, including edge bias, small-target errors, no prediction, near miss, far miss, and toolbar confusion, to enable systematic diagnosis of model behavior in clinical GUI settings. By shifting evaluation from isolated grounding to workflow-aware sequential reasoning, MedSPOT establishes a realistic and safety-critical benchmark for assessing multimodal models in medical software environments. Code and data are available at: https://github.com/Tajamul21/MedSPOT.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rozain Shakeel, Abdul Rahman Mohammad Ali, Muneeb Mushtaq, Tausifa Jan Saleem, Tajamul Ashraf. 2026-03-20. MedSPOT: A Workflow-Aware Sequential Grounding Benchmark for Clinical GUI. https://arxiv.org/abs/2603.19993

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Band-Attention Modulation Network for Robust Face Forgery Detection

Face forgery detection faces critical challenges in generalizing to unseen manipulation techniques and remaining robust under image compression, which often obscures subtle artifacts. Existing methods typically rely on fixed filters or coarse band separation, lacking the adaptability to learn task-specific spectral cues. To address this, we propose the Band-Attention Modulation Network (BAM-Net), a novel framework that pioneers learnable, fine-grained modulation of frequency components for forgery detection. At its core is the Band-Attention Modulation (BAM) mechanism, which transforms an image into its Discrete Cosine Transform (DCT) spectrogram and learns to dynamically reweight frequency bands along anti-diagonals. This process effectively enhances forgery-related spectral signatures while suppressing less informative ones, simulating an adaptive "inverse compression" that counters information loss. The modulated frequency information is then fused with the spatial domain to guide a lightweight yet effective spatial backbone equipped with distance-decayed attention for comprehensive feature extraction. Extensive experiments on FaceForensics++, Celeb-DF, and DFDC datasets demonstrate that BAM-Net achieves state-of-the-art performance. More importantly, it exhibits exceptional generalization in cross-dataset, cross-compression, and cross-manipulation scenarios, underscoring the vital role of adaptive frequency band modulation in building robust forgery detectors.

cs.CV↗

Comparing YOLOv11 and YOLOv8 for instance segmentation of occluded and non-occluded immature green fruits in complex orchard environment

This study conducted a comprehensive performance evaluation on YOLO11 (or YOLOv11) and YOLOv8, the latest in the "You Only Look Once" (YOLO) series, focusing on their instance segmentation capabilities for immature green apples in orchard environments. YOLO11n-seg achieved the highest mask precision across all categories with a notable score of 0.831, highlighting its effectiveness in fruit detection. YOLO11m-seg and YOLO11l-seg excelled in non-occluded and occluded fruitlet segmentation with scores of 0.851 and 0.829, respectively. Additionally, YOLOv11x-seg led in mask recall for all categories, achieving a score of 0.815, with YOLO11m-seg performing best for non-occluded immature green fruitlets at 0.858 and YOLOv8x-seg leading the occluded category with 0.800. In terms of mean average precision at a 50\% intersection over union (mAP@50), YOLOv11m-seg consistently outperformed, registering the highest scores for both box and mask segmentation, at 0.876 and 0.860 for the "All" class and 0.908 and 0.909 for non-occluded immature fruitlets, respectively. YOLO11l-seg and YOLOv8l-seg shared the top box mAP@50 for occluded immature fruitlets at 0.847, while YOLO11m-seg achieved the highest mask mAP@50 of 0.810. Despite the advancements in YOLO11, YOLOv8n surpassed its counterparts in image processing speed, with an impressive inference speed of 3.3 milliseconds, compared to the fastest YOLO11 series model at 4.8 milliseconds, underscoring its suitability for real-time agricultural applications related to complex green fruit environments. Future work will compare YOLO26 (YOLOv26) and YOLO27 (YOLOv27) using the same dataset and training protocol.

cs.CV↗

Cross-Task Generalization in Handwriting-Based Alzheimer's Screening via Vision Language Adaptation

Alzheimer's disease (AD) is a prevalent neurodegenerative disorder for which early detection is critical. Handwriting, which can be disrupted by subtle motor and cognitive decline, provides a non-invasive and cost-effective window for AD screening. Existing handwriting-based AD studies mostly rely on online trajectories and hand-crafted features, while the influence of handwriting task type on diagnostic performance and cross-task generalization remains underexplored. Meanwhile, large-scale vision--language models have demonstrated strong transfer and adaptation ability in natural-image anomaly detection and several medical modalities, such as chest X-ray and brain MRI. However, handwriting-based disease detection remains unexplored within this paradigm. To address this gap, we introduce a lightweight Cross-Layer Fusion Adapter (CLFA) framework that repurposes Contrastive Language--Image Pre-training (CLIP) for handwriting-based AD screening. CLFA inserts multi-level adapters into a frozen visual encoder, combining cross-layer feature fusion with depthwise 2D convolution on patch grids to capture both local stroke irregularities and higher-level handwriting structure. This design progressively aligns pretrained vision--language representations with AD-related handwriting cues and supports transfer from supervised source tasks to task-disjoint unseen target tasks. On the Darwin dataset, under the subject-disjoint cross-task protocol, averaged over all 600 task-disjoint source-target pairs, CLFA achieves 74.63\% AUC, 74.85\% accuracy, and 73.72\% F1 score, outperforming the best competing model by 2.15, 1.79, and 1.87 percentage points, respectively.

cs.CV↗