Search arXivSearch

arXiv · 2603.29251

Synthesis imaging with a lunar orbit array: II. Impacts of instrument-induced phase errors

Abstract

A lunar orbit interferometer array suffers from a number of systematics. Beyond systematics induced by the imaging algorithm itself and thermal noise considered in Paper I, phase errors due to instrumental inconsistency between receivers, geometric error in baseline determination, and clock synchronization error between satellites will also affect synthesis imaging with the space array. In this paper, we model different sources of phase errors and quantify their impacts on all-sky and patchy-sky map-making, respectively, for the ultra-long wavelength sky ($f\lesssim30$ MHz), using the Discovering the Sky at the Longest wavelength (DSL) mission (also known as the Hongmeng mission) as an example. We find that in the scheme of all-sky imaging, the angular power spectrum can be suppressed uniformly for various sources of phase errors. To ensure a reconstruction of large-scale structures with $\gtrsim 95\%$ of the angular power spectrum, the phase error should be controlled below $\sim 12^\circ$ on the random instrumental component, or below $\sim 12^\circ$ for constant deviation, or below $1.1$ ns on the temporal component. With multiple baseline measurements, the baseline determination errors below $1$ m can also meet the requirement. In the scheme of patchy-sky imaging, the S/N of point source detections does not change significantly, except with instrumental phase errors or at high frequencies. The impact of geometric phase error is relatively stronger in the patchy-sky imaging with higher resolution because longer baselines are used and fewer times of baseline measurements can be averaged over within an integration time. When scaled with wavelength, these results set the basic reference for instrumental requirements for future space interferometers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Meng Zhou, Furen Deng, Yidong Xu, Li Zhou, Xuelei Chen. 2026-03-31. Synthesis imaging with a lunar orbit array: II. Impacts of instrument-induced phase errors. https://arxiv.org/abs/2603.29251

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM