Search arXivSearch

arXiv · 2604.02166

Data Sieving for Scalable Real-Time Multichannel Nanopore Sensing

Abstract

High-throughput solid-state nanopore experiments generate continuous MHz-rate data streams in which only a small fraction of data contains informative molecular information. This creates storage and processing bottlenecks that limit experimental scalability. We introduce Data Sieving, a GPU-accelerated acquisition framework that integrates real-time event detection directly into the measurement pipeline and selectively stores and allows real-time analysis of snapshots around molecular translocations. The system employs a lightweight rolling-average and min-max trigger to identify event candidates in parallel across channels. This architecture reduces stored data volume by up to 98% while preserving complete molecular signatures across a wide temporal range, from microsecond-scale protein dynamics to second-scale nucleic acid nanoparticle events. Continuous baseline monitoring enables autonomous closed-loop actuation; in high-concentration DNA experiments, automatic declogging restored pore conductance, reducing the time spent in a non-productive clogged state to near-zero and without interrupting parallel measurements. Validated across DNA, protein, and nucleic acid nanoparticle measurements, Data Sieving links data storage directly to molecular information content rather than experiment duration, enabling scalable, real-time operation of parallel nanopore sensors. The approach provides a hardware-agnostic foundation for long-duration, high-bandwidth single-molecule experiments and other event-driven sensing platforms. By using algorithms intrinsically compatible with low-latency digital architectures, this framework provides a clear path toward high-bandwidth, highly multiplexed recording across hundreds of individual nanopore channels in both solid-state and biological pores.

Explore related subjects

Keep this discovery

BibTeXRIS

Matteo Cartiglia, Natan Biesmans, Wannes Peeters, Wouter Botermans, Koen Ongena, Liam Vandekerckhove, Wouter Renckens, Eric Beamish, Elizabeth Skelly, Kirill A. Afonin, Pol van Dorpe, Sanjin Marion. 2026-04-02. Data Sieving for Scalable Real-Time Multichannel Nanopore Sensing. https://arxiv.org/abs/2604.02166

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det