Search arXivSearch

arXiv · 2604.02443

ITACA revisited: Ion Tracking Apparatus with CMOS ASICs

Abstract

High-pressure xenon gas TPCs with electroluminescent amplification (HPXeEL) provide detailed topological reconstruction of charged-particle trajectories, offering a distinctive two-electron signature for neutrinoless double beta decay ($0\beta\beta\nu$) searches. We have recently proposed ITACA, a detector concept that images both the electron track and the corresponding ion track, carried by the positive ions drifting in the opposite direction. While electrons drift rapidly to the anode for standard EL imaging, the positive ions drift slowly to the cathode with millimetre-scale diffusion, allowing time to determine the event energy and barycenter and to position a movable ion detector at the projected arrival point of the ion cloud. We present a conceptual design of the ITACA detector, addressing key feasibility questions. First, we define the detector geometry and operating parameters for a 1-tonne-scale instrument at 15 bar, including a modular tiled electroluminescent structure. Second, we present the conceptual design of the Magnetically Actuated Rotor System (MARS), the mechanism that positions the ion sensor at any $(r, \theta)$ coordinate below the cathode, and show that the expected movement time is fast enough to retain $\sim95\%$ of the drift volume for ion detection, while not significantly perturbing the gas on the scales of the ion drift. Third, we propose using a Topmetal CMOS ASIC-based ion detector as an alternative to the molecular sensor approach described in our original work, enabling real-time, 3D imaging of the ion track without the need for offline laser scanning. Finally, we estimate the sensitivity of the proposed apparatus, showing that enhanced topological discrimination from the ion track, combined with an ultra-low background design, allows exploration of $0\beta\beta\nu$ half-lives in excess of $10^{28}$ yr.

Explore related subjects

Keep this discovery

BibTeXRIS

J. J Gómez-Cadenas, L. Arazi, G. Martínez-Lema, J. Renner, S. R. Soleti, S. Torelli. 2026-04-02. ITACA revisited: Ion Tracking Apparatus with CMOS ASICs. https://arxiv.org/abs/2604.02443

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det