Search arXivSearch

arXiv · 2604.11727

Characterization of the 20-inch Photomultiplier Tubes for RENE Detector

Abstract

To address the Reactor Antineutrino Anomaly (RAA) observed in neutrino experiments, the Reactor Experiment for Neutrino and Exotics (RENE) has been initiated using a liquid scintillation detector. In this study, we investigate the characteristics of two 20-inch Hamamatsu R12860 photomultiplier tubes (PMTs) intended for installation in the RENE detector. The charge and timing responses of the PMTs were evaluated at both the nominal and target gains expected during actual operation. In particular, gain non-uniformity arising from the large-diameter photocathode with a box-and-line type dynode structure was examined, and the maximum gain variation was measured. The occurrence rate, timing, and charge distributions of late pulses and afterpulses were also investigated to characterize the specific response features of the R12860 PMT. The results reported in this study will aid in the interpretation of signals from the RENE detector and serve as a reference for estimating potential systematic uncertainties in RENE data. Furthermore, these findings are expected to provide valuable information for other experiments employing the same type of PMTs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Junkyo Oh, Byeongsu Yang, Cheong Heo, Daeun Jung, Dong Ho Moon, Eungyu Yun, Hyun Woo Park, Jae Sik Lee, Jisu Park, Ji Young Choi, Kyung Kwang Joo, Ryeong Gyoon Park, Sang Yong Kim, Sunkyu Lee, Insung Yeo, Myoung Youl Pac, Jee-Seung Jang, Eun-Joo Kim, Hyunho Hwang, Junghwan Goh, Wonsang Hwang, Jiwon Ryu, Jungsic Park, Kyu Jung Bae, SeoBeom Hong, Hyunsoo Kim, Dojin Kim, Jonghee Yoo, Seunghwan Choi, Wonjun Lee, Jubin Park, Myung-Ki Cheoun, Intae Yu. 2026-04-13. Characterization of the 20-inch Photomultiplier Tubes for RENE Detector. https://arxiv.org/abs/2604.11727

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det