Search arXivSearch

arXiv · 2604.16189

A two-color dual-oscillator infrared free-electron laser

Abstract

We report on the design and performance of a two-color dual-oscillator infrared free-electron laser (FEL). The mid-infrared (MIR) FEL at the Fritz Haber Institute (FHI FEL) has been upgraded to include a second oscillator FEL beamline that permits lasing in the far-infrared (FIR) regime from 4.5 μm to 175 μm. In addition, a 500 MHz kicker cavity has been installed downstream of the electron accelerator. It allows to deflect electron bunches of up to 50 MeV energy alternately left and right by an angle of {\pm}2°. It can, thus, split the high-repetition-rate (1 GHz) electron bunch train from the accelerator into two bunch trains of 500 MHz repetition rate each; one is steered to the MIR FEL and the other one to the new FIR FEL. In this two-color mode of simultaneous, synchronized operation the wavelengths in both FELs can be tuned independently over wide ranges of up to a factor of four each by undulator-gap variation. In addition, two-color operation is also available at reduced repetition rates (e.g. 55.6 MHz of both MIR and FIR pulses), as needed for some applications. This unique two-color mode opens up a wealth of novel user applications such as, MIR-FIR pump-probe experiments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wieland Schöllkopf, Sandy Gewinner, Marco De Pas, Heinz Junkes, Sebastian Kray, William Kirstaedter, William B. Colson, David H. Dowell, Stephen C. Gottschalk, John W. Rathke, Tom J. Schultheiss, Alan M. M. Todd, Lloyd M. Young, Akash Chandra Behera, América Y. Torres-Boy, Martin Wolf, Alexander Paarmann, Gert von Helden, Gerard Meijer. 2026-04-17. A two-color dual-oscillator infrared free-electron laser. https://arxiv.org/abs/2604.16189

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-power attosecond X-ray free-electron lasers: physics and design strategy

Attosecond pulses from X-ray free-electron laser (XFEL) have opened new opportunities for probing ultrafast electronic dynamics on the Angstrom--attosecond spatiotemporal scale. Most attosecond XFEL concepts rely on generating an ultrashort high-current spike through either external laser modulation or accelerator-based beam manipulation. Despite their different implementations, these approaches share the same essential physics, namely that the XFEL amplification is confined to a short effective lasing window within the electron beam. However, existing studies are often scheme-specific and do not yet provide a unified quantitative picture of how fundamental electron-beam properties constrain high-power attosecond performance. In this work, we investigate the general physics and scheme-independent requirements for generating high-power attosecond X-ray pulses from a short current spike. From the perspective of post-saturation superradiant evolution, we show that the effective lasing length of the electron beam governs both the attainable peak power and the pulse duration. We further examine the distinct roles of slice energy spread, slice emittance, energy chirp, undulator tapering, and transverse beam tilt. Our results reveal the trade-off between peak power, pulse shortening, and single-spike probability, and provide facility-independent guidelines for optimizing electron-beam phase-space manipulation toward terawatt-class attosecond XFEL operation.

physics.acc-ph

Bayesian Optimization of The Relativistic Heavy Ion Collider Luminosity via $s^*$ Control

Maximizing luminosity at the interaction point (IP) requires the collision location $s_{IP}$ to coincide with the longitudinal position of the minimum beta function, $s^$. Accurate optics measurements and control of $s^$ are therefore essential for luminosity optimization. At the Relativistic Heavy Ion Collider (RHIC), average horizontal beta-beat measurements between operating IPs are approximately $20%$, with significant variation in measured $s^*$. Precise control of the beam waist position $s^$ is particularly challenging for modern high-energy colliders with short bunch lengths and large crossing angles. We present an online Bayesian optimization (BO) application using the GPTune framework to optimize sPHENIX luminosity through $s^$ control at RHIC. GPTune was first validated at the RHIC Electron Beam Ion Source (EBIS), where it achieved up to a $70%$ increase in beam intensity over the baseline, although experienced operators could reach similar performance with longer manual tuning. The framework was subsequently deployed during sPHENIX operations. Using an intensity-normalized Zero-Degree Calorimeter (ZDC) signal as the optimization objective, due to the unavailability of the live sPHENIX MVTX signal, GPTune identified local luminosity maxima, recovered from intentionally degraded $s^$ configurations, and revealed residual horizontal and vertical waist offsets in the interaction region. These results demonstrate the robustness and efficiency of Bayesian optimization for real-time collider tuning under noisy, time-varying conditions. The $s^$ control methodology provides a promising tool for precision luminosity optimization and is particularly relevant to next-generation short-bunch colliders such as the Electron-Ion Collider (EIC).

physics.acc-ph

Ultralow Mean Transverse Energy and High Quantum Efficiency Cryogenic Bialkali Photocathode for MHz-Repetition-Rate Electron Sources

Simultaneously achieving high quantum efficiency (QE), ultralow mean transverse energy (MTE), and robust long-term operation under conditions relevant to continuous-wave (CW) X-ray free-electron lasers (XFELs) remains a central challenge for semiconductor photocathodes. This challenge arises from the trade-off between QE and MTE, as well as the difficulty of maintaining stable operation in high-field CW electron guns. Here we demonstrate a cryogenic K2CsSb photocathode that simultaneously achieves high QE, ultralow MTE, and robust long-term operation in a CW gun under XFEL-relevant operating conditions. Under cryogenic operation, the photocathode achieves an MTE of 50 meV while sustaining a QE of 5.4%. Milliampere-level CW current, including operation at 5 mA, was demonstrated together with an approximately 20-day operational history. The observations are consistent with improved carrier survival and/or surface escape in photocathodes prepared using the optimized recipe. These results show that the practical QE-MTE trade-off can be substantially mitigated in cryogenic bialkali photocathodes and provide a practical pathway toward high-brightness electron sources for CW XFELs and energy-recovery linacs.

physics.acc-ph