Search arXivSearch

arXiv · 2604.17101

Line-scanning Brillouin microscopy with multiplexed two-stage VIPA spectrometer

Abstract

Confocal Brillouin microscopy enables high-resolution mechanical imaging but has low acquisition speed, partly due to its pixel-by-pixel mapping strategy. Line-scanning Brillouin microscopy (LSBM) significantly improves imaging speed by utilizing a multiplexing approach. However, current method is limited to a single-stage virtually imaged phased array (VIPA) spectrometer with insufficient capability of suppressing noise. Consequently, an absorptive gas chamber is often used to help reject excessive elastically scattered light. This approach requires specific tunable laser sources whose frequencies (e.g., around 780 nm) are locked to the absorption line of the gas chamber. Here, we developed a multiplexed Brillouin spectrometer for LSBM that increased the noise suppression to 57 dB without using any gas chamber. This is achieved by cascading two VIPA etalons with parallel dispersion axes in the spectrometer, where the first VIPA acts as a band-pass filter and the second as spectrum analyzer. We demonstrated its performance by acquiring Brillouin images of bio-printed phantoms with an inverted co-axial LSBM. This gas-chamber-free approach can expand the implementation of LSBM to other wavelengths where Brillouin scattering is more efficient and commercial laser sources are readily available.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chenjun Shi, Jitao Zhang. 2026-04-18. Line-scanning Brillouin microscopy with multiplexed two-stage VIPA spectrometer. https://doi.org/10.1364/oe.601790

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Active Fourier Spectroscopy: From fixed sampling protocols to adaptive measurement

Fourier-transform spectroscopy (FTS) is based on the Nyquist-Shannon theorem, which dictates a strict sampling protocol for the measurement of continuous signals. Here we introduce Active Fourier Spectroscopy (AFS), a generalization of FTS in which measurements are still taken in the Fourier-conjugate delay domain, but where the most informative acquisition points are selected adaptively and the spectrum is reconstructed by sequential, uncertainty-aware inference rather than by fixed-grid Fourier inversion. Our approach relies on a theoretical insight that the Nyquist condition applies only under complete ignorance about the system under investigation, and shows how to systematically improve upon it when prior knowledge exists. Because AFS recovers conventional FTS whenever the prior is uninformative, its performance never falls below that of conventional sampling. We demonstrate AFS for optical spectroscopy in three settings vital to research and medicine: clinical FTIR-based blood plasma analysis, optical metrology of structured laser beams, and hyperspectral imaging with an RGB camera. In each case AFS reaches a higher target reconstruction quality from far fewer acquisitions and provides complete uncertainty quantification in real time, propagated rigorously through downstream analysis.

physics.optics

Memory in Integrated Photonic Neural Networks: From Physical Mechanisms to Neuromorphic Architectures

The rapid scaling of artificial neural networks has exposed fundamental limitations of conventional von Neumann computing architectures. In these systems, the physical separation between memory and processing creates a bottleneck, as computational capabilities outpace the ability of memory and interconnects to supply and retrieve data. In contrast, biological neural systems inherently co-localize computation and memory through distributed, dynamical processes. Neuromorphic computing seeks to emulate this paradigm by leveraging physical substrates whose intrinsic dynamics simultaneously encode and process information. Among emerging platforms, silicon photoncis offer a compelling approach due to its high bandwidth, low-loss propagation, and inherent parallelism. This review examines the role of memory in integrated photonic neuromorphic systems, with emphasis on the physical mechanisms that provide volatile (short-term) and non-volatile (long-term) memory in silicon-on-insulator and hybrid silicon-on-insulator platforms. Drawing inspiration from digital, biological, and photonic memory architectures, we classify existing approaches based on their underlying physical principles. We cover implementations ranging from delay lines and slow-light structures to multistable dynamics and structural memory based on charge trapping and phase-change materials. We then discuss how these mechanisms support photonic neural network architectures, including feed-forward, reservoir computing, spiking and hybrid optoelectronic recurrent systems, and assess their relevance for time-dependent singal-processing tasks such as channel equalization in telecommunications. This review aims to establish a unified framework for understanding memory and learning in neuromorphic photonics and outlines key challenges and opportunities for scalable, energy-efficient neuromorphic hardware.

physics.optics

Exoplanet Detection Using Adaptive Quantum-Optimal Measurement

Detecting terrestrial exoplanets in the habitable zones of nearby stars remains a critical challenge. Such planets can be \(10^8\) to \(10^{10}\) times fainter than their host stars and lie at diffraction-limited angular separations, where starlight strongly obscures the companion signal. Here we present an adaptive quantum measurement method for estimating the number, positions, and brightnesses of mutually incoherent point sources in the sub-Rayleigh, ultra-high-contrast regime, operating at contrasts down to \(10^{-8}\) -- five orders of magnitude beyond previous quantum imaging approaches to exoplanet detection. The method adopts a spatial-mode basis that is updated to maximize the quantum Fisher information per detected photon. Estimation is performed by maximum likelihood in log-brightness coordinates, and the source count is determined by Bayesian-information-criterion (BIC) model selection directly from photon-count statistics, without a tunable detection threshold. For point sources within sub-Rayleigh separations and with brightness ratios spanning eight orders of magnitude, the method reconstructs complete scenes with a mean success rate of \(72.5\%\). Furthermore, it is robust to misalignment, maintaining a \(71.3\%\) success rate under offsets of up to six pixels. These results demonstrate that terrestrial exoplanets can be detected below the Rayleigh limit, a regime previously inaccessible to direct imaging.

physics.optics