Search arXivSearch

arXiv · 2605.02969

The Catastrophic Consequences of Agnosticism for Life Searches and a Possible Workaround

Abstract

Planned and ongoing searches for life, both biological and technological, confront an epistemic barrier concerning false positives - namely, that we don't know what we don't know. The most defensible and agnostic approach is to adopt diffuse (uninformative) priors, not only for the prevalence of life, but also for the prevalence of confounders. We evaluate the resulting Bayes factors between the null and life hypotheses for an idealized experiment with $N_{pos}$ positive labels (biosignature detections) among $N_{tot}$ targets with various priors. Using diffuse priors, the consequences are catastrophic for life detection, requiring at least ${\sim}10^4$ (for some priors ${\sim}10^{13}$) surveyed targets to ever obtain "strong evidence" for life. Accordingly, an HWO-scale survey with $N_{tot}{\sim}25$ would have no prospect of achieving this goal. A previously suggested workaround is to forgo the agnostic confounder prior, by asserting some upper limit on it for example, but we find that the results can be highly sensitive to this choice - as well as difficult to justify. Instead, we suggest a novel solution that retains agnosticism: by dividing the sample into two groups for which the prevalence of life differs, but the confounder rate is global. We show that a $N_{tot}=24$ survey could expect 24% of possible outcomes to produce strong life detections with this strategy, rising to $\geq50$% for $N_{tot}\geq76$. However, AB-testing introduces its own unique challenges to survey design, requiring two groups with differing life prevalence rates (ideally greatly so) but a global confounder rate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

David Kipping. 2026-05-03. The Catastrophic Consequences of Agnosticism for Life Searches and a Possible Workaround. https://arxiv.org/abs/2605.02969

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM