Search arXivSearch

arXiv · 2605.05453

Active Edge Silicon Sensors Fabricated With Edge Ion Implantation and Microwave Annealing for Dopant Activation

Abstract

Silicon detectors typically require an insensitive area around their periphery to accommodate guard rings, which help maintain the electric field uniformity around edge pixels and isolate the high leakage current from the physical edges of the detector. Minimization of this insensitive region is desirable for applications in high-energy physics, X-ray experiments, and medical imaging. Existing active edge technology offers a solution for reduction or total elimination of the insensitive region, via a continuation of the highly doped backside up the sidewalls of the device. However, current methods for realizing this technology are complex and expensive. We propose a new technique that simplifies the fabrication of highly doped edges using side ion implantation and microwave annealing. Tests demonstrating the feasibility of this proposed process were performed on a set of sensors, and current versus bias voltage measurements probing the edge effects were performed before and after the edge implantation and annealing. To aid in interpretation of the results, TCAD simulations of the test devices were performed. Significant improvement in the edge leakage current is observed, indicating the promise of this simplified process for fabrication of active edge sensors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Andrew Gentry, Julie Segal, Angela Kok, Christopher Kenney, Sally Seidel. 2026-07-01. Active Edge Silicon Sensors Fabricated With Edge Ion Implantation and Microwave Annealing for Dopant Activation. https://arxiv.org/abs/2605.05453

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det