Search arXivSearch

arXiv · 2605.29063

Accelerating HEVC Intra Partitioning via a CNN-Hierarchical Attention Transformer Hybrid

Abstract

The recursive quad-tree partitioning in High Efficiency Video Coding (HEVC) incurs considerable computational overhead, with exhaustive rate-distortion optimization for CTU partition prediction consuming the dominant share of encoding time. Although partition prediction through deep learning has emerged as a viable encoding accelerator, an architectural dichotomy remains largely unaddressed: CNNs are computationally efficient but spatially myopic due to their localized effective receptive fields, failing to capture long range semantic relationships and repetitive textures; conversely, transformer based architectures are better at capturing global context but incur prohibitive CPU latency, a critical liability that impedes deployment which is predominantly CPU-bound. This paper introduces Hybrid Fast Vision Transformer (HFViT), a hybrid architecture designed to accelerate HEVC intra-mode partition prediction. HFViT fuses a reparameterized depthwise-separable convolutional backbone with a Hierarchical Attention Transformer (HAT) mechanism, leveraging a carrier token scheme to enable efficient global information propagation at sub-quadratic complexity. Post-training structural fusion collapses batch normalization into preceding layers to further reduce latency. Comprehensive evaluation reveals the efficacy of HFViT in accelerating HEVC intra-encoding across resolutions. On standard JCT-VC test sequences, HFViT reduces the average VMAF BD-rate penalty by 2.4, 2.6, and 7.9 percentage points on Classes A, B and E, respectively, as compared to the competing ETH-CNN baseline while maintaining CPU inference latency within 8% of the CNN baseline and surpassing it on GPU by 40%, establishing practical viability for real-time encoder integration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Krishna Kumar Sharma, Somdyuti Paul. 2026-05-27. Accelerating HEVC Intra Partitioning via a CNN-Hierarchical Attention Transformer Hybrid. https://arxiv.org/abs/2605.29063

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV