Search arXivSearch

arXiv · 2606.01946

Closed-Form Pose Estimation of Endoluminal Medical Devices via Gradiometer-Based Electromagnetic Localization System

Abstract

Embedded magnetic tracking holds highly attractive prospects for remote navigation of endoluminal medical devices. However, existing six-degree-of-freedom pose recovery approaches often require pre-calibrated workspace field maps or iterative nonlinear optimization. This letter presents a Gradiometer-Based Electromagnetic Localization System (GELS), a closed-form tracking framework that uses a compact magnetometer array as an embedded quasi-gradiometer to estimate local magnetic fields and gradient tensors. These quantities are mapped by the Euler homogeneous relation to displacements between source and array, from which multi-source Procrustes registration recovers the array orientation and position using at least three non-collinear sources. The algorithm requires known source positions and array geometry, but no pre-calibrated workspace field maps, initial pose guesses, or calibrated excitation-source moments. The recovered pose also enables a proof-of-concept sub-level dipole localization task by serving as a mobile magnetic reference frame. Benchtop experiments across sensor-array configurations and excitation modes demonstrate sequence-averaged position errors of \SI{10.80}{\milli\meter}--\SI{15.57}{\milli\meter}, a fastest update rate of \SI{14.49}{\hertz}, and a median solver runtime of \SI{172.00}{\micro\second}. A perturbation-based error propagation analysis further identifies inter-sensor inconsistency and dipole-model mismatch as the dominant accuracy limits, thereby informing future sensor array and magnetic source design for further reducing pose-estimation error.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhiwei Wu, Jiahao Luo, Yubo Pu, Siyi Wei, Yuankai Chen, Jinhui Zhang. 2026-06-01. Closed-Form Pose Estimation of Endoluminal Medical Devices via Gradiometer-Based Electromagnetic Localization System. https://arxiv.org/abs/2606.01946

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

J-PARSE: Jacobian-based Projection Algorithm for Resolving Singularities Effectively in Inverse Kinematic Control of Serial Manipulators

J-PARSE is an algorithm for smooth first-order inverse kinematic control of a serial manipulator near kinematic singularities. The commanded end-effector velocity is interpreted component-wise, according to the available mobility in each dimension of the task space. First, a substitute ''Safety'' Jacobian matrix is created, keeping the aspect ratio of the manipulability ellipsoid above a threshold value. The desired velocity is then projected onto non-singular and singular directions, and the latter projection scaled down by a factor informed by the altered mobility. A right-inverse of the non-singular Safety Jacobian is applied to the modified command. In the absence of joint limits and collisions, this ensures safe transition into and out of low-mobility configurations, guaranteeing locally stable reaching behavior towards target poses within, on the boundary of, and outside the workspace. The behavior is further guaranteed to be locally asymptotically stable if the starting and target configurations are not exactly singular, even if they are nearly singular. Velocity control with J-PARSE is benchmarked against approaches from the literature, illustrating its use of a single tuning parameter to simultaneously achieve high reaching accuracy and stable behavior. Applications in teleoperation, servoing, and learning are demonstrated. Videos and code are available at https://jparse-manip.github.io/.

cs.RO

NeMo-map: Neural Implicit Flow Fields for Spatio-Temporal Motion Mapping

Safe and efficient robot operation in complex human environments can benefit from good models of site-specific motion patterns. Maps of Dynamics (MoDs) provide such models by encoding statistical motion patterns in a map, but existing representations use discrete spatial sampling and typically require costly offline construction. We propose a continuous spatio-temporal MoD representation based on implicit neural functions that directly map coordinates to the parameters of a Semi-Wrapped Gaussian Mixture Model. This removes the need for discretization and imputation for unevenly sampled regions, enabling smooth generalization across both space and time. Evaluated on two public datasets with real-world people tracking data, our method achieves better accuracy of motion representation and smoother velocity distributions in sparse regions while still being computationally efficient, compared to available baselines. The proposed approach demonstrates a powerful and efficient way of modeling complex human motion patterns and high performance in the trajectory prediction downstream task. The code is publicly available at https://github.com/test-bai-cpu/nemo-map.

cs.RO

Spatiotemporal Calibration of Doppler Velocity Logs for Underwater Robots

The calibration of extrinsic parameters and clock offsets between sensors for high-accuracy performance in underwater SLAM systems remains insufficiently explored. Existing methods for Doppler Velocity Log (DVL) calibration are either constrained to specific sensor configurations or rely on oversimplified assumptions, and none jointly estimate translational extrinsics and time offsets. We propose a Unified Iterative Calibration (UIC) framework for general DVL sensor setups, formulated as a Maximum A Posteriori (MAP) estimation with a Gaussian Process (GP) motion prior for high-fidelity motion interpolation. UIC alternates between efficient GP-based motion state updates and gradient-based calibration variable updates, supported by a provably statistically consistent sequential initialization scheme. The proposed UIC can be applied to IMU, cameras and other modalities as co-sensors. We release an open-source DVL-camera calibration toolbox. Beyond underwater applications, several aspects of UIC-such as the integration of GP priors for MAP-based calibration and the design of provably reliable initialization procedures-are broadly applicable to other multi-sensor calibration problems. Finally, simulations and real-world tests validate our approach.

cs.RO