Breast cancer is the most common cancer among women, and mammography remains the primary modality for early detection. Because mammography uses ionizing radiation, accurate estimation of normalized glandular dose (DgN) is important for risk assessment. Recent breast dosimetry models, including TG-282, incorporate population-based glandular tissue distributions; however, patient-specific glandular distributions remain unknown from conventional mammographic projections. In previous work (Smith, Dey et al., 2025), glandular fraction (GF) maps were estimated from a single mammographic projection. While these maps determine glandular path length along each projection ray, they do not uniquely define glandular tissue depth. In this work, we propose a framework for estimating a patient-specific range of DgN from a projection-derived GF map. Using simulated data, glandular tissue was distributed to the top, center, and bottom of the breast volume using Siddon ray-tracing. These configurations preserved the GF map while producing maximum, intermediate, and minimum DgN values. Monte Carlo simulations were performed, and DgN was normalized to entrance air kerma. DgN varied by up to a factor of three solely due to differences in glandular tissue depth, despite identical GF maps and visually indistinguishable projection images. Using randomized realizations derived from TG-282 glandular distributions for Cranio-Caudal (CC) and Medio-Lateral Oblique (MLO) views, dose ratios were calculated relative to central glandular placement. Central placement overestimated DgN by less than 5 and 15 percent on average for MLO and CC distributions respectively, whereas centroid-based placement underestimated dose by up to 25 percent. These results indicate that patient-specific bounds on DgN can be estimated from limited mammographic information and that central placement provides a conservative dose estimate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lacey L. Medlock, Murtuza S Taqi, Bryce Smith, Joyoni Dey. 2026-06-09. Range of Normalized Glandular Dose for Mammography Using Patient-Specific Glandular Fractions. https://arxiv.org/abs/2606.11071

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph