Background-Pressure Effects on Charge-Exchange Measurements in Plasma Flows at Elevated Pressures

Abstract

Charge-exchange (CEX) collisions can affect measurements of plasma plumes and neutralized ion flows in vacuum facilities, particularly when the background gas pressure increases and the CEX mean free path becomes comparable to the characteristic plume or facility dimension. Here, we investigate that regime in the plasma plume of a gridded ion source operating with a 400 eV argon ion beam. The fast-ion flux and low-energy ion flux were measured using a retarding potential analyzer (RPA) and planar probes, while the fast-neutral flux was inferred from deposited-power measurements with a thermal flux probe using a power-balance analysis. The low-energy ion flux increases with both background gas pressure and axial distance and its detection also depends on probe geometry. After the fast-ion component is isolated, its attenuation is described more accurately by an analytical reduced semi-empirical quasi-2D model that includes charge exchange and the experimentally observed plume divergence than by a one-dimensional attenuation law. The inferred fast-neutral flux also increases with pressure; however, the model underpredicts it at small axial distance and overpredicts it at elevated pressure and larger axial distance. This discrepancy suggests additional angular and collisional effects, as well as possible fast-neutral production near or inside the ion source, that are not captured by the present model. These results show that background gas pressure affects both the plasma plume and the diagnostic response, and that complementary electrostatic, thermal, and energy-selective diagnostics are required to distinguish source behavior from facility-induced effects.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ivan Romadanov, Stanislav Musikhin, Je-Hoi Mun, Sang Ki Nam, Yevgeny Raitses. 2026-06-09. Background-Pressure Effects on Charge-Exchange Measurements in Plasma Flows at Elevated Pressures. https://arxiv.org/abs/2606.11411

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Scalable Terbium-149 Production from Highly Enriched Gadolinium-150 Targets

We propose a two-stage production method to overcome existing supply-constraints for the alpha-emitter $^{149\mathrm{g}}$Tb, a promising candidate for Targeted Alpha Therapy (TAT) with no existing globally scalable production pathway. Although awaiting experimental measurement of the $^{150}$Gd(p,2n)$^{149\mathrm{g}}$Tb cross section, the proposed method could produce $^{149\mathrm{g}}$Tb at clinical scale and beyond on readily available proton cyclotrons, enabled by production of the extinct but long-lived isotope $^{150}$Gd, a pure alpha emitter with a 1.79 million year half-life. Stage one generates $^{150}$Gd feedstock by irradiating natural Eu or enriched $^{151}$Eu with $\gtrsim$10 MeV protons, neutrons or photons. Stage two produces $^{149\mathrm{g}}$Tb from fabricated $^{150}$Gd targets by driving the $^{150}$Gd(p,2n)$^{149\mathrm{g}}$Tb reaction with $\gtrsim$14 MeV protons, accessible on over 700 reported cyclotrons worldwide. Fast fusion neutrons appear to offer the most scalable pathway for $^{150}$Gd production: even with a large $^{149 \mathrm{g}}$Tb dose size of 1 GBq and 40 million administered doses/yr, we estimate this would require neutrons produced by only 6.8 megawatts of steady-state deuterium-tritium power to produce the required $^{150}$Gd, far below expected capacity in the next decade. The route described here, if validated, would enable $^{149\mathrm{g}}$Tb supply at the scale needed to support clinical development of $^{149\mathrm{g}}$Tb-based TAT.

physics.plasm-ph

Analytic toroidal 3D MHD equilibria and steady Euler flows with invariant surfaces

Families of explicit analytic solutions of the magnetohydrodynamic equilibrium equations are presented, equivalent to steady incompressible Euler flow. The solutions are non-axisymmetric and possess exact nested toroidal flux surfaces. No expansion is made in inverse aspect ratio or in the deviation from axisymmetry. The magnetic field and flux surfaces are given explicitly in Cartesian coordinates using elementary functions. The field, current density, and scalar pressure are smooth over the toroidal domain. The pressure gradient vanishes only on the magnetic axis. One family of solutions has uniform rotational transform $ι=2$, while another family has a sheared $ι$ profile. These counterexamples to Grad's conjecture are valuable for understanding the existence and regularity of 3D equilibria and for testing numerical codes.

physics.plasm-ph

Dynamics of an impulse dielectric barrier discharge in pure ammonia gas using electrical characteristics and imaging analysis

A glow nanosecond discharge from a plane-to-plane impulse dielectric barrier discharge (iDBD) with ammonia gas has been characterised by employing fast imaging and electrical diagnostics. More precisely, the aim of this study is to investigate the dynamics of the discharge establishment under various conditions of applied voltage, pressure, and gas gap. The comparison between the current measurements and the image analysis exposes a strong correlation between the fast excitation and ionization wave velocity and the rising current velocity. This correlation has been found only for diffuse mode discharge since a front wave could be clearly defined, denoted as the luminous propagation front (LPF). Furthermore, this correlation is supported by a proportionality factor of 1.5 10$^{-3}$ which is systematic over the studied conditions. Further investigations are considered to evaluate the relevance of such a value over more parameters.

physics.plasm-ph