Search arXivSearch

arXiv · 2606.16177

In-Plane Q Anisotropy of Higher-Order XBARs

Abstract

128$^\circ$Y-cut lithium niobate (LN) laterally field-excited higher-order antisymmetric bulk acoustic resonators (XBARs) have attracted interest for high-frequency acoustic devices thanks to their high electromechanical coupling coefficient ($k^2$), high quality factor ($Q$) from low metal coverage ratio, and thickness-defined resonant frequency. So far, the in-plane orientation of these resonators is commonly chosen to maximize $k^2$, thereby maximizing bandwidth. More recently, in-plane-rotated XBARs in 128$^\circ$Y-cut LN have been built to provide greater design flexibility in filter synthesis. However, the in-plane anisotropy of $Q$ has been far less explored. This leaves an important gap in understanding whether the propagation direction that determines $k^2$ also affects $Q$. In this work, we investigate the anisotropic $Q$ of higher-order antisymmetric modes (namely, A$_3$, A$_5$, and A$_7$) in 500-nm-thick 128$^\circ$Y-cut LN on Si. By characterizing resonator performance in various in-plane orientations, we observe that both Bode $Q$ and $Q_{\mathrm{3dB}, f_p}$ show minimum values at 90$^\circ$ to the material x-axis and maximum values around 0$^\circ$, following a trend similar to $k^2$. The A$_3$, A$_5$, and A$_7$ modes around 10.4, 17, and 24 GHz exhibit averaged Bode $Q$/$Q_{\mathrm{3dB}, f_p}$ values of 735/556, 204/149, and 59/37, respectively. At 90$^\circ$, the average Bode $Q$ values are reduced to 66, 9, and 12. Finite element analysis (FEA) results suggest that the orientation-dependent degradation of $Q$ near 90$^\circ$ is associated with stronger transverse displacement near the inactive and anchor regions, resulting in enhanced energy leakage. These results reveal an orientation-dependent loss pathway in 128$^\circ$Y-cut LN XBARs and provide design guidance for jointly optimizing $k^2$ and $Q$.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Byeongjin Kim, Ian Anderson, Ruochen Lu. 2026-06-15. In-Plane Q Anisotropy of Higher-Order XBARs. https://arxiv.org/abs/2606.16177

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

physics.app-ph

Pendellösung length-scale neutron and X-ray interferometry

Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 $μ$m and 350 $μ$m, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.

physics.app-ph