Search arXivSearch

arXiv · 2606.17959

A High-Precision Frequency Locking Method Based on All-Phase FFT Demonstrated on a Crystal Oscillator with Rubidium Clock Reference

Abstract

This article proposes a novel frequency-locking method based on frequency-domain unbiased phase estimation (FDUPE) for high-precision frequency control. By performing weighted recombination of the acquired data followed by Fourier-transform processing, the phase at the center of the data segment can be estimated without bias, making the method suitable for frequency-locking applications. The principle of the proposed method is analyzed, and an electronic prototype is developed to experimentally validate its feasibility. In the prototype, analog-to-digital converters (ADCs) are used for signal digitization, and a field-programmable gate array (FPGA) is used to implement the FDUPE algorithm. A digital proportional-integral-derivative (PID) controller is also implemented on the FPGA to provide feedback for accurate frequency locking. In the experiment, a (10~\mathrm{MHz}) voltage-controlled oscillator (VCO) with a free-running Allan deviation of (1 \times 10^{-9}) at (1~\mathrm{s}) is used as the device under test (DUT), while a rubidium atomic clock with an Allan deviation of (2 \times 10^{-11}) at (1~\mathrm{s}) serves as the high-stability reference source. Experimental results show that the proposed system achieves excellent locking performance, reducing the standard deviation of frequency fluctuations from (12.75~\mathrm{mHz}) root-mean-square (rms) in the free-running state to (0.88~μ\mathrm{Hz}) rms after locking. Correspondingly, the Allan deviation at (10~\mathrm{s}) is reduced from (9.6 \times 10^{-10}) to (1.45 \times 10^{-14}), representing a five-order-of-magnitude improvement in frequency stability.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Qibin Zheng, Kang Xu, Jiacheng Yang, Liguo Zhou, Li Ding, Xianfeng Jiang, Zhaohui Bu. 2026-06-16. A High-Precision Frequency Locking Method Based on All-Phase FFT Demonstrated on a Crystal Oscillator with Rubidium Clock Reference. https://arxiv.org/abs/2606.17959

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det