Search arXivSearch

arXiv · 2606.19182

Optimized Multi-Contrast Self-Supervised MRI Reconstruction using Learned k-space Partitioning

Abstract

Objective: Deep Learning has shown promise in accelerating MRI by reconstructing high-quality images from under-sampled data. While recent work has leveraged multi-contrast information to improve reconstruction performance, these methods rely on supervised learning, which requires fully sampled k-space for training. One method, self-supervised learning via data undersampling (SSDU), enables direct training on under-sampled k-space by partitioning it into two sets, with a network mapping between the two. In this work, we improve MRI self-supervised MRI reconstruction with two modifications. Methods: We propose a multi-contrast self-supervised learning framework that jointly trains on multiple under-sampled contrasts without requiring fully sampled k-space data as a reference. Moreover, we learn an optimal self-supervised data partitioning for each contrast in an end-to-end manner, further enhancing reconstruction quality. Specifically, we learn an optimal partitioning probability distribution, which is sampled to generate a mask for partitioning. Results: Experiments on two publicly available multi-contrast MRI datasets demonstrate the improved reconstruction quality of our proposed self-supervised multi-contrast learned partitioning method compared to the current single-contrast self-supervised learning methods. We also demonstrate that learning the partitioning of k-space data further enhances the fidelity of reconstructions. Conclusion: Multi-contrast reconstruction combined with learned partitioning improves reconstruction fidelity over single-contrast self-supervised MRI reconstructions. Significance: Our method can facilitate higher image fidelity and/or accelerated MRI protocol times compared to previous self-supervised methods, and without requiring fully sampled k-space for training.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Brenden Kadota, Charles Millard, Mark Chiew. 2026-06-17. Optimized Multi-Contrast Self-Supervised MRI Reconstruction using Learned k-space Partitioning. https://arxiv.org/abs/2606.19182

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Dipole-lets: a new multiscale decomposition for MR phase and quantitative susceptibility mapping

Nondipolar phase contributions can generate severe streaking artifacts during quantitative susceptibility mapping (QSM) inversion. We propose Dipole-lets, a dipole-adapted multiscale decomposition designed to identify phase components associated with streaking artifacts before and during susceptibility inversion. Dipole- lets combine an undecimated radial decomposition with an angular partition based on proximity to the magic cone. The resulting coefficients emphasize phase components near the magic cone, where nondipolar contributions may become relatively prominent. This information was incorporated into QSM reconstruction through a data- driven fidelity weight and a Dipole-let-based regularizer that models an additional nondipolar phase component. The methods were evaluated using modified simulated QSM data and an in vivo dataset. The data-driven weighting reduced streaking artifacts while preserving anatomical detail and improved quantitative reconstruction metrics compared with magnitude-weighted TV. The Dipole-let regularizer achieved streaking suppression comparable to L1-QSM and lower reconstruction error in the modified simulated dataset. In vivo experiments further demonstrated the applicability of the proposed approach to data with strong susceptibility-induced phase perturbations. Dipole-lets provide a multiscale representation for characterizing phase components associated with streaking artifacts and incorporating this information into QSM reconstruction, reducing streaking while preserving relevant susceptibility structures, and providing a flexible basis for future QSM reconstruction methods.

eess.IV

MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical Imaging

In the field of medical imaging, AI-assisted techniques such as object detection, segmentation, and classification are widely employed to alleviate the workload of physicians and doctors. However, single-task models are predominantly used, overlooking the shared information across tasks. This oversight leads to inefficiencies in real-life applications. In this work, we propose MTMed3D, a novel end-to-end Multi-task Transformer-based model to address the limitations of single-task models by jointly performing 3D detection, segmentation, and classification in medical imaging. Our model uses a Transformer as the shared encoder to generate multi-scale features, followed by CNN-based task-specific decoders. The proposed framework was evaluated on the BraTS 2018 and 2019 datasets, achieving promising results across all three tasks, especially in detection, where our method achieves better results than prior works. Additionally, we compare our multi-task model with equivalent single-task variants trained separately. Our multi-task model significantly reduces computational costs and achieves faster inference speed while maintaining comparable performance to the single-task models, highlighting its efficiency advantage. To the best of our knowledge, this is the first work to leverage Transformers for multi-task learning that simultaneously covers detection, segmentation, and classification tasks in 3D medical imaging, presenting its potential to enhance diagnostic processes. The code is available at https://github.com/fanlimua/MTMed3D.git.

eess.IV

VideoPulse: Neonatal heart rate and peripheral capillary oxygen saturation (SpO2) estimation from contact free video

Remote photoplethysmography (rPPG) enables contact free monitoring of vital signs and is especially valuable for neonates, since conventional methods often require sustained skin contact with adhesive probes that can irritate fragile skin and increase infection control burden. We present VideoPulse, a neonatal dataset and an end to end pipeline that estimates neonatal heart rate and peripheral capillary oxygen saturation (SpO2) from facial video. VideoPulse contains 157 recordings totaling 2.6 hours from 52 neonates with diverse face orientations. Our pipeline performs face alignment and artifact aware supervision using denoised pulse oximeter signals, then applies 3D CNN backbones for heart rate and SpO2 regression with label distribution smoothing and weighted regression for SpO2. Predictions are produced in 2 second windows. On the NBHR neonatal dataset, we obtain heart rate MAE 2.97 bpm using 2 second windows (2.80 bpm at 6 second windows) and SpO2 MAE 1.69 percent. Under cross dataset evaluation, the NBHR trained heart rate model attains 5.34 bpm MAE on VideoPulse, and fine tuning an NBHR pretrained SpO2 model on VideoPulse yields MAE 1.68 percent. These results indicate that short unaligned neonatal video segments can support accurate heart rate and SpO2 estimation, enabling low cost non invasive monitoring in neonatal intensive care.

eess.IV